Key points

From the paper's conclusion
  • We then developed two scalable frameworks to automate key processes of local evaluation: selection of a candidate series for device inference and generation of report-derived labels.

Abstract

Introduction: Artificial intelligence (AI)-enabled imaging device performance may vary across institutions due to differences in disease prevalence, patient demographics, and acquisition protocols. Routine local evaluation, including pre-deployment baseline testing and post-deployment monitoring, remains limited by manual data curation. A large language model (LLM)-as-a-judge approach using existing radiology reports provides a method of performing local evaluation. Methods: We established PACS-integrated LLMs in HIPAA-compliant environments. We then developed two scalable frameworks to automate key processes of local evaluation: selection of a candidate series for device inference and generation of report-derived labels. We applied these frameworks to 4,000 consecutive non-contrast head CT examinations from two hospitals to evaluate agreement between radiology reports and Purple AI Hyper Insight-ICH, a commercial intracranial hemorrhage detection device. Results: For series selection, we used a three-tiered, traffic-light approach across 31,422 available series to select a single series for device inference in 3,976 examinations. For radiology report field extraction, we refined an LLM prompt with three steps: initial binary classification, characterization of discordance between the binary classification prompt output and device output, and a comprehensive prompt (featuring 28 structured fields that were informed by the preceding stages). The positive percent agreement (PPA) depended on the definition of positive cases based on the comprehensive prompt fields: it was 87.7% (79.2 to 95.0%) using similar criteria to many published studies (acute or acute-on-chronic, non-minimal, non-equivocal hemorrhage), yet was lower when including chronic, minimal or equivocal ICH. The negative percent agreement (NPA) was 94.7% (94.0 to 95.4%). Subgroup analyses demonstrated that discrepancies involving a positive device output commonly occurred in the setting of recent intracranial surgery and intracranial hyperdense (non-hemorrhagic) lesions. Conclusion: A PACS-integrated LLM approach, together with scalable frameworks for series selection and label generation, can provide radiologists with local insights about AI-enabled device performance. These insights may help radiologists interpret device outputs in clinical practice, particularly in scenarios associated with greater device-report discordance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers