Effects of a High-Airflow Fan-Attached Garment on Thermoregulatory and Physiological Responses During Physical Activity in Hot Environments: A Randomized Crossover Trial
K. Hayashi, M. Wanifuchi, H. Ito, Y. Urushizawa, Y. Tomioka, F. Takayama
Key points
From the paper's conclusion- Conclusions: The high-airflow (80 L/s) fan-attached garment effectively prevented an increase in core body temperature and mitigated cardiovascular and thermoregulatory strain during moderate physical activity, even in hot and humid environments.
Abstract
Objectives: Although fan-attached garments are widely used, conventional airflow rates have shown limited efficacy in suppressing core body temperature elevation during physical activity. We aimed to investigate the effects of a high-airflow fan-attached garment on core body temperature and physiological strain during physical activity in hot environments under different humidity levels. Methods: Seven healthy adult men completed four randomized crossover trials involving two environmental conditions - wet bulb globe temperatures of 25 degrees C (36 degrees C, 20% relative humidity) and 31 degrees C (36 degrees C, 60% relative humidity) - and two garment conditions: control and fan-attached garment (80 L/s airflow). Each trial consisted of a 10-min thermoneutral rest, 10-min hot rest, and 60-min continuous cycle ergometer exercise (60 W). We evaluated rectal and skin temperatures, heart rate, microclimate environment, body mass change, and subjective sensations. Results: At a wet bulb globe temperature of 31 degrees C, the fan-attached garment significantly suppressed the increase in rectal temperature compared with the control garment at 60 min of exercise (difference: 0.50 degrees C, p < 0.001), with rectal temperature remaining unchanged from baseline (+0.11 degrees C, p = 0.077). Exercise heart rate (difference: 31.5 beats/min, p < 0.001) and body mass loss (difference: 0.5 kg, p = 0.001) were also significantly reduced with the fan-attached garment. Microclimate humidity was significantly lower with the fan-attached garment throughout exercise in both environments (p < 0.001). Conclusions: The high-airflow (80 L/s) fan-attached garment effectively prevented an increase in core body temperature and mitigated cardiovascular and thermoregulatory strain during moderate physical activity, even in hot and humid environments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Undershirt Layering and Fabric Breathability Affect the Skin-Clothing Microclimate and Local Physiological Responses During Running in the HeatTextiles · 2026
- Physiological responses to 10 days of heart rate-clamped heat acclimation in hot-dry and hot-humid environments.Journal of sports sciences · 2026
- Heat Acclimatization Through Progressive Overdressing in Fire Academy Students.Journal of occupational and environmental medicine · 2026
- Development of moisture-responsive fabrics and ventilated garments in high-temperature field environmentsFashion and Textiles · 2026
- Wearable Printed Heaters: Evaluations of Novel Garments Used in High-Performance Sport.Sensors (Basel, Switzerland) · 2026
- Effects of training intensities and heat chamber sitting on heat acclimatization under extreme high-temperature and high-humidity environmentFrontiers in Physiology · 2026