Transportability of polysomnography-derived sleep physiological fingerprints across cohorts, measurement modalities and time: a four-axis evaluation in four cohorts
Q. Deng, Y. Chen, N. Ma, X. Lou
Key points
From the paper's conclusion- We propose four axes of transportability and test them in the Sleep Heart Health Study (n = 5,614), MESA Sleep (n = 2,012), ADNI (n = 2,286) and MrOS Sleep (2,911 men; 1,026 re-examined after 6.37 years; 3,928 scored nights).
Abstract
Epidemiological evidence linking sleep to Alzheimer disease (AD) relies predominantly on self-reported sleep, whereas cohorts with polysomnography (PSG) and cohorts with AD biomarkers rarely share participants. Multifractal long-range-interdependency representations classify obstructive sleep apnoea severity accurately across cohorts, but whether such a physiological fingerprint can be transported between cohorts, between measurement modalities or over time has not been evaluated. We propose four axes of transportability and test them in the Sleep Heart Health Study (n = 5,614), MESA Sleep (n = 2,012), ADNI (n = 2,286) and MrOS Sleep (2,911 men; 1,026 re-examined after 6.37 years; 3,928 scored nights). Axis A1, cross-cohort construct convergence, passed: PSG-derived Sleep Coupling Disruption Index loadings agreed between SHHS and MESA (cosine 0.986; Wasserstein distance 0.0487). Axis A2, incremental validity beyond the apnoea-hypopnoea index, failed: the fully adjusted hazard ratio for incident cardiovascular disease was 1.009 (95% CI 0.941-1.085; p = 0.83) and the C-index was 0.8079 with or without the index; in MrOS, adding a multifractal coupling fingerprint increased R-squared by 0.00058 (likelihood-ratio p = 0.399). Axis A3, proxy identifiability, failed: the reliability ratio linking portable subjective complaints to objective physiological burden was 1.95 x 10-5, with a bootstrap 95% upper bound of 0.00261 and 0.0027 for a semantically optimised proxy, far below the 0.25 floor required for measurement-error correction. Under classical error this implies a 370-fold sample-size inflation; Monte-Carlo power at n = 10,000 was 0.177. A nominally significant association between night-time behaviour and dementia severity would require an implausible true physiological effect of 28.7 standard deviations, and it reversed to -0.0554 after adjustment for total neuropsychiatric burden. The prespecified ADNI primary outcome, plasma pTau217, was null (beta = 0.0033, p = 0.911), as were the MrOS six-year cognitive complaint outcome (beta = -0.0204, p = 0.375) and a 35-event self-reported dementia endpoint (OR = 0.921, p = 0.679). Axis A4, temporal stability, failed: six-year test-retest reliability was r = 0.157 (95% CI 0.096-0.216) for the fingerprint versus r = 0.455 (0.405-0.502) for AHI, despite stable concurrent validity (rho = 0.380 and 0.328 with same-night AHI). Spearman-Brown projection indicates that approximately nine nights must be averaged for the fingerprint to reach a reliability of 0.60, compared with two for AHI. A fingerprint can therefore be reproducible without being transportable. We provide a four-question decision workflow and an eight-item minimum reporting set; subjective sleep complaints should not be substituted for objective sleep physiology in aetiological inference.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Two Axes of Sleep, One Heart: Dissociating Objective Sleep-Disordered Breathing From Subjective Sleep Duration in Cardiac RiskmedRxiv · 2026
- Long-range interdependencies aware signal analysis for rapid and accurate obstructive sleep apnea prediction.Nature communications · 2026
- The EEG-Respiratory Gap: a deep learning biomarker associated with long-term mortality in obstructive sleep apneamedRxiv · 2026
- Association between stage-specific sleep bout durations and obstructive sleep apnea severity: a variable-domain functional regression approachFrontiers in Sleep · 2026
- Sequential Associations of Sleep Architecture, Nocturnal Oxygenation, and Respiratory Disturbance With a Composite PSG-Derived Rhythm-Event Index.Brain and behavior · 2026
- Analysis of sleep quality and associated factors in patients with metabolic syndrome: a retrospective cross-sectional studyBMC Public Health · 2026