From the paper's conclusion
  • Objective: To determine whether executable encodings of three ocular hypertension guidelines, produced under a prospectively frozen pipeline barring author-defined operationalisations, are judged faithful by independent clinical review before execution, and to characterise findings on retained content, exclusions and divisions.

Abstract

Objective: To determine whether executable encodings of three ocular hypertension guidelines, produced under a prospectively frozen pipeline barring author-defined operationalisations, are judged faithful by independent clinical review before execution, and to characterise findings on retained content, exclusions and divisions. Methods: Under a registered protocol, one ophthalmologist encoded European Glaucoma Society (EGS), American Academy of Ophthalmology (AAO) and National Institute for Health and Care Excellence (NICE) guidelines; a second encoded a sample. A gate barred author-defined operationalisations. Before execution, two other ophthalmologists reviewed branches, exclusions and division records against predefined materiality criteria. Results: The gate admitted 0, 2 and 1 branches (EGS, AAO, NICE) from 748, 322 and 198 eligible units. Review of these branches raised no primary finding (AAO 0/2, NICE 0/1); at these denominators, uninformative. In the overlap, one NICE omission (laser trabeculoplasty) was judged material. The exclusion reviewer flagged material source-stated decision content in 601/2,109, 216/234 and 151/179 excluded passages. A masked post-hoc reader agreed with 31/50, 11/50 and 28/50 sampled flags; he judged 1/246 passages directly relevant to the initial treat-or-observe decision and 0/100, 0/68 and 8/78 needed to preserve a retained unit's meaning. No synthetic case resolved to observation. Conclusion: Without author-defined choices, few branches were instantiable and none resolved to observation. Fidelity was not determinable at these denominators; exclusion flags were reader-dependent, and some NICE exclusions may have carried meaning needed by retained units. Exclusion review shows what a scope restriction sets aside; its reproducibility must be established before it measures fidelity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Clinical review before execution of executable guideline encodings: a prospective registered study of three ocular hypertension guidelines — Science Skim