Pulsed X-Ray CT with Temporally Aware Reconstruction for Three-Dimensional Endovascular Guidance: Phantom Feasibility Study
N. Azimi, A. Brian-Choux, S. Araujo, B. Jacob, E. Haneda, E. Adamy, E. Cohen, S. Sharon,
Key points
From the paper's conclusion- In an anthropomorphic endovascular phantom, temporally aware reconstruction of retrospectively sparsified data localized robotically manipulated devices within one reconstructed voxel diagonal.
Abstract
Background: Endovascular fluoroscopy provides limited depth information. Projection-level x-ray pulsing and prior-image reconstruction could enable volumetric CT updates from sparse projection data. Purpose: To assess whether pulsed sparse-view CT combined with temporally aware reconstruction could accurately localize robotically manipulated endovascular devices in a phantom. Materials and Methods: We compared true pulsed acquisitions with matched retrospective sparsification (4--180 projections) in a modular phantom. Eight robotically generated device configurations in an anthropomorphic endovascular phantom were scanned with 1248 projections. Data were retrospectively sparsified to 6, 12, 24, 32, and 52 projections and reconstructed using filtered backprojection and a temporally aware prior-image method. Localization errors were measured relative to full-view filtered-backprojection measurements. Analyses were descriptive. Results: Mean CT number differences between true pulsed and matched retrospectively sparsified images were 4.8--6.2 Hounsfield units; corrected standard deviations were 27.5--29.9 Hounsfield units. Sparse-view filtered backprojection obscured device segments at 6 and 12 projections, whereas temporally aware reconstruction depicted both devices at all projection counts. At 6 projections, median centerline, guidewire-tip, and tip-to-vessel-wall errors were 0.82 mm (interquartile range, 0.10 mm), 0.71 mm (0.12 mm), and 0.03 mm (0.28 mm), respectively. All localization errors were below the 0.944-mm reconstructed voxel diagonal. Conclusion: True pulsed and matched retrospectively sparsified acquisitions showed similar CT numbers in a modular phantom. In an anthropomorphic endovascular phantom, temporally aware reconstruction of retrospectively sparsified data localized robotically manipulated devices within one reconstructed voxel diagonal.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative analysis of numerical methods for X-ray 3D reconstruction from sparse viewsarXiv · 2026
- Dual-energy cardiac DSA imaging using a dual-layer flat-panel detector: in vivo validation studyarXiv · 2026
- A Temporal-Consistency Segmentation-Inpainting Virtual Subtraction for Roadmap Imaging.Journal of imaging informatics in medicine · 2026
- Every IVUS Frame in Its Place: A Zero-Install Browser Tool for Registering Intravascular Ultrasound to the Coronary Angiogram, and a Path to Angiography-Only Plaque ImagingarXiv · 2026
- Diffusion Posterior Sampling for Angiographic Reconstruction using Limited Angle and Sparse View data for 4D-DSA.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2026
- Toward real-time alignment of 3D CT and 2D X-ray with multi-stage CNNsComputer Assisted Surgery · 2026