Clinician gaze as a supervisory signal for electrocardiogram deep learning: a matched-control proof-of-concept study
A. Mukherjee, S. Shergill, C. S. Ang
Key points
From the paper's conclusion- Conclusion In this sparse experiment, gaze-only optimisation engaged its target without demonstrating case-specific learning beyond a population viewing prior, and matched controls showed that the resulting diagnostic deterioration was not attributable to correctly matched gaze.
Abstract
Aims To assess what evidence is required to attribute an apparent effect of clinician-gaze supervision on an electrocardiogram (ECG) deep-learning model to gaze itself, separating target engagement, case specificity, and diagnostic preservation. Methods and results Ten ECG stimuli interpreted by 63 readers yielded 12-lead gaze targets for nine consultants and 20 clinicians. A pretrained 23-output ECG network was fine-tuned with gaze-only loss on eight ECGs per cross-validation fold. Held-out gaze cosine improved modestly (consultants 0.858 to 0.872; all clinicians 0.884 to 0.898), but untrained training-fold mean gaze agreed better (0.929 and 0.951). Lead-occlusion concordance was weak (mean Spearman {rho} 0.236). On 2,198 PTB-XL fold-10 ECGs, macro area under the receiver operating characteristic curve (AUROC) fell from 0.922 to 0.893 after gaze-only tuning; uniform and permuted controls also reduced performance. In a post hoc experiment combining PTB-XL diagnostic cross-entropy with gaze loss, macro AUROC was approximately 0.923 in diagnostic-only, real-gaze, uniform and permuted arms, but real-gaze targets were barely fitted even on training ECGs (cosine 0.858 to 0.860). Conclusion In this sparse experiment, gaze-only optimisation engaged its target without demonstrating case-specific learning beyond a population viewing prior, and matched controls showed that the resulting diagnostic deterioration was not attributable to correctly matched gaze. Joint training preserved source-domain discrimination, but because gaze targets were barely fitted, whether gaze adds diagnostic value remains untested. Claims that human viewing has shaped a model require mean-gaze, matched-null and function-preserving controls.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Teaching an ECG model where to look does not make it more robust to missing leads: a pre-registered comparison of guideline-based attention guidance with random lead maskingmedRxiv · 2026
- IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for ElectrocardiogramarXiv · 2026
- Deep learning for ECG-based cardiovascular diagnosis: a review of model architecturesEvolutionary Intelligence · 2026
- Artificial intelligence-based automated interpretation of images of electrocardiograms: development and multinational validation of ECG-GPTEuropean Heart Journal - Digital Health · 2026
- LEAP-LLM: Preserving lead-time structure for question-conditioned ECG interpretationarXiv · 2026
- Foundation models for electrocardiogram interpretation: clinical implicationsEuropean Heart Journal · 2025