Optoretinographic measurements of cone photoreceptor function in disease-affected retinas.
Reddikumar Maddipatla, Elain Guo, Maciej M Bartuzel, Yao Cai, Anqi Zhang, Kareem Moussa, Glenn C Yiu, Robert J Zawadzki,
Key points
From the paper's conclusion- Here, we applied velocity-based ORG using a clinical-grade swept-source optical coherence tomography (OCT) system to assess photoreceptor function in disease-affected human retinas and healthy controls.
Abstract
1Optoretinography (ORG) provides a noninvasive approach for measuring stimulus-evoked photoreceptor responses in the living human retina, but its application to retinal disease using clinically translatable imaging systems remains limited. Here, we applied velocity-based ORG using a clinical-grade swept-source optical coherence tomography (OCT) system to assess photoreceptor function in disease-affected human retinas and healthy controls. Following pupil dilation and dark adaptation, repeated B-scans were acquired at 400 Hz during visible-light stimulation using a phase-sensitive 100-kHz, 1060-nm swept-source OCT system. Stimulus-evoked optical path length changes between the inner segment/outer segment junction (IS/OS) and cone outer segment tips (COST) were used to quantify cone outersegment responses. Healthy retinas exhibited rapid and reproducible responses characterized by an initial outer-segment contraction followed by elongation, whereas disease-affected retinas exhibited quantitatively reduced or altered response amplitudes and temporal dynamics. ORG also detected functional improvement following treatment in a vitamin-A-deficient retina. These findings demonstrate the ability of velocity-based ORG to quantitatively detect photoreceptor dysfunction and functional change using a clinically compatible OCT platform, supporting its potential as a noninvasive functional biomarker for retinal disease and therapeutic response.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Phase-based optoretinographic measurements of cones with a raster-scanning adaptive optics OCT are highly repeatableBiomedical Optics Express · 2026
- Split-spectrum amplitude decorrelation optoretinography for functional imaging of mouse photoreceptors.Biomedical optics express · 2026
- Long-duration volumetric optoretinography enables measurement of retinal recovery dynamics after photostimulation.Optics letters · 2026
- Evaluating Human Rod Photoreceptor Function Using Pixelwise Intensity-Based OptoretinographyTranslational Vision Science & Technology · 2026
- Spatially or temporally resolved phase-based optoretinography with actively tracked point-scanning optical coherence tomography.Optics letters · 2026
- Optoretinography reveals rapid rod photoreceptor movement upon rhodopsin activationLight Science & Applications · 2026