Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy
Y. Wang, J. He, W. Liu, X. Xu, B. Li, Y. Li, B. Wang, M. Liu
Key points
From the paper's conclusion- Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module.
Abstract
Background Hand microvasculature is conventionally presented through diagrams, cadaveric atlases and specialized optical instruments, while conventional clinical radiography cannot resolve individual capillary loops (5-15 m lumen) in vivo, which dominate cutaneous oxygen exchange. Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module. The single-file application runs offline on a laptop or, over local HTTPS, on a phone as an installable app. Results Its 3D atlas contains 136 named structures per hand in six systems from open Z-Anatomy/BodyParts3D meshes, plus a literature-parameterized capillary layer. The NVC module renders a 200x, 1.2-mm field with six deterministic patterns and quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. A lumped model reports nine estimates (SIM); a physics module shows that a 10-m capillary occupies 0.07 of a 150-m detector pixel; with iodinated contrast it retains {approx}0.016% effective contrast, about 60x below a 1% detection threshold; unenhanced blood is {approx}270x lower. The 2D stage renders in 2.9 ms per frame; system merging reduces atlas draw calls from 136 to 6. Conclusions The camera-overlay layers are templates, the atlas macro-anatomy is open mesh data, and the capillary layer is sampled. No patient data are used. The instrument is a product prototype, not a medical device, and provides a reproducible framework for making multi-scale microvascular reasoning visible.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Every IVUS Frame in Its Place: A Zero-Install Browser Tool for Registering Intravascular Ultrasound to the Coronary Angiogram, and a Path to Angiography-Only Plaque ImagingarXiv · 2026
- The OxyCam: A novel hand-held vital microscope for quantitative measurement of microcirculatory perfusion and oxygenationJournal of Intensive Medicine · 2026
- Proyecciones Ópticas de la Capilaroscopía MetabólicaRevista Hambatu Science · 2026
- Simultaneous imaging of arterial and venous territories in human cutaneous microcirculation: An ex vivo anatomical model.Journal of anatomy · 2026
- Functional dermoscopy integrated by cellular-resolution Mirau-based optical coherence microscopy.Biomedical optics express · 2026
- Bedside microcirculatory assessment in complex regional pain syndrome: a feasibility study of incident dark-field handheld vital microscopyFrontiers in Pain Research · 2026