Inter-protocol reproducibility of multi-shell diffusion MRI metrics across major neuroimaging study protocols.
Jamie Wren-Jarvis, Valentin Stepanov, Benjamin Ades-Aron, Jenny Chen, Subah Mehrin, Nalini Jeet, Santiago Coelho, Ricardo Coronado-Leija,
Key points
From the paper's conclusion- These findings demonstrate good reproducibility of quantitative higher-order diffusion MRI metrics across commonly used multi-shell acquisition protocols, which can be further improved by aligning b-values, providing a foundation for data pooling, harmonization, and normative modeling in large-scale neuroimaging studies.
Abstract
Diffusion MRI is a core component of large-scale neuroimaging initiatives, yet the reproducibility of quantitative dMRI metrics across different acquisition protocols remains unclear. We acquired seven multi-shell diffusion protocols representative of major consortia and clinical settings on a single scanner in 41 healthy adults, isolating protocol effects from hardware and site variability. A linear mixed-effects model was used to estimate the inter-protocol coefficient of variation (CV) and the intraclass correlation coefficient (ICC) for diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), and standard model imaging (SMI) metrics across atlas-based white matter regions. Rank agreement was assessed with Kendall's W , and repeated scans of one protocol provided a reference for test-retest variability. Overall, inter-protocol variability was low, with median CVs of 2.9-6.1% for DTI, 3.7-5.0% for DKI, and 3.0-4.7% for SMI metrics. Protocols ranked subjects consistently ( W = 0.73-0.86) but agreed less in absolute value (ICC = 0.31-0.66), with fractional anisotropy (FA) being the most stable metric. Acquisition parameters, including TE, b -values, and signal-to-noise ratio jointly explained 53-93% of the inter-protocol variance. Differences in the b-values used for DTI and DKI estimation were particularly important for the diffusivities: matching b-values across protocols reduced the median inter-protocol CV for MD from 5.0% to 1.8%, with smaller reductions for mean kurtosis (MK), axial kurtosis (AK) and the axonal water fraction ( f ). These findings demonstrate good reproducibility of quantitative higher-order diffusion MRI metrics across commonly used multi-shell acquisition protocols, which can be further improved by aligning b -values, providing a foundation for data pooling, harmonization, and normative modeling in large-scale neuroimaging studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reproducibility of Diffusion, Shape, and Connectivity Metrics Across Scanners: Implications for Multi-Site Tractography.NeuroImage · 2026
- Divergence from Diffusion Tensor: a discriminant diffusion marker from single shell MRImedRxiv · 2026
- Sensitivity of diffusion MRI to white matter pathology: a comparison between ROI-based effect size and TBSS analysis under different diffusion protocols, field strengths and post-processing strategiesarXiv · 2026
- A Time-Dependent Diffusion MRI Framework for Clinical Characterisation of Human Brain Cellular ArchitecturemedRxiv · 2026
- Highly replicable multisite patterns of adolescent white matter maturation.Neuron · 2026
- Echo-time dependence of apparent microstructural metrics in diffusion MRI.Physics in medicine and biology · 2026