Volumetric Cross-Amplitude Modulation (VxAM) for Transcranial Gas Vesicle Imaging.
Andrew S Weitz, Hatim Belgharbi, Masashi Sode, Rebecca M Jones-Sinnott, Rohit Nayak, Trevor Fochtman, Mikhail G Shapiro, Paul A Dayton,
Key points
From the paper's conclusion- We present the first implementation of xAM on a fully sampled two-dimensional matrix array, extending the half-aperture split of conventional xAM to a family of 2D sub-aperture partitions on a 32x32-element Vermon probe (7.81 MHz, 300 m element pitch).
Abstract
Cross-amplitude modulation (xAM) is a commonly used pulse sequence for non-destructive, quasi-artifact-free detection of gas-vesicle (GV) contrast agents, but it has so far been limited to two-dimensional cross-sections acquired with one-dimensional linear arrays. We present the first implementation of xAM on a fully sampled two-dimensional matrix array, extending the half-aperture split of conventional xAM to a family of 2D sub-aperture partitions on a 32 × 32-element Vermon probe (7.81 MHz, 300 µ m element pitch). Angular spectrum simulations compared three primary bisections (X-axis, Y-axis, and diagonal ( D 1 , D 2 )), and the selected Y-split was tested experimentally in GV-loaded tissue-mimicking phantoms. We also simulated an electronic asymmetric-angle sweep as an alternative to the robotic translation used in the experiments, and measured contrast through an ex vivo mouse skull. The non-emissive regions between the elevation panels of the Vermon probe accounted for most of the simulated differences among partitions, through both the continuity of the aperture parallel to the bisector plane and the side-lobe structure. At a 6° steering angle, the Y-split gave a contrast-to-tissue ratio (CTR) of ≈ 29 dB for single frames and ≈ 49 dB with 100-frame averaging without the skull, and a contrast-to-noise ratio (CNR) of ≈ 8 dB for single frames and ≈ 12 dB with 100-frame averaging through the skull, where the inclusion remained resolvable. These results give design rules for xAM on matrix arrays. The through-skull result comes from a single ex vivo specimen, and in vivo work is the next step toward non-invasive, longitudinal, three-dimensional monitoring of GV-labeled glioblastoma and other targets of nonlinear contrast agents.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Real-time volumetric imaging of cells and molecules in deep tissues with Takoyaki ultrasoundNature Communications · 2026
- Multi‑stage singular value decomposition for ultrafast ultrasound imaging of microbubbles.Ultrasonics · 2026
- Noninvasive photoacoustic computed mesoscopy for longitudinal brain imagingScience Advances · 2026
- Transient cavitation dynamics of vaporized perfluorocarbon nanodroplets measured with an acoustical camera.The Journal of the Acoustical Society of America · 2026
- Ultrasonic Nonlinear Contrast-Enhanced Imaging Using Chirp-Coded Excitation and Volterra Filtering.Ultrasonic imaging · 2026
- Image-domain assessment and quantitative evaluation of acoustic cavitation using singular-value decomposition and magnitude-based spectral gating of B-mode imaging.Ultrasonics sonochemistry · 2026