False-Positive Calls of Reimplemented Published Analyses for Covert Command-Following on Electroencephalograms Recorded Without Study Commands.
Alon Gorenshtein, Yosef Adiniaev, Yiftach Barash, Eyal Klang, Oved Daniel
Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA. · BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Key points
From the paper's conclusion- Interpretation: Reimplemented published analyses called up to 27% of patients positive without commands, more with repeated runs.
Abstract
OBJECTIVE: To measure how often published electroencephalographic analyses for covert command-following call patients positive without commands, and their detection of genuine responses. METHODS: This cross-sectional study applied 11 reimplemented published analyses to electroencephalograms without commands: 974 clinical electroencephalography patients and, with rules fixed, 730 new patients; 38 with prolonged disorders of consciousness; and 544 comatose patients after cardiac arrest. Outcomes: false calls (share called positive) against a 5% benchmark, and genuine-response detection. RESULTS: Three of 10 command-following analyses called significantly more than 5% of clinical electroencephalography patients positive, replicated in new patients: Goldfine 2011, a spectral test, 23.3% (95% CI, 20.2%-26.6%), above its stated 5%; du Bois 2026, a criterion for entry to brain-computer interface training, 22.2% (95% CI, 19.2%-25.5%); and Guger 2018, a P300 accuracy threshold, 13.8% (95% CI, 11.5%-16.3%), near its approximate 12% chance rate (24.5% over 2 runs). The other 7 called 0.0% to 6.9%. After cardiac arrest: 11.5% to 27.3%. All 3 detected genuine responses. Identified contributors: a variance ignoring within-command dependence (Goldfine 2011), selection over configurations and times (du Bois 2026) and a permissive threshold (Guger 2018). Goldfine 2011's command-level correction, fixed before testing, called 0.8% of new patients and 2.4% after arrest, detecting 93.4% of stroke imagery-versus-rest sessions but few between imagery types. INTERPRETATION: Reimplemented published analyses called up to 27% of patients positive without commands, more with repeated runs. A positive result needs its complete call rule's false-call rate and detection at that rate; imagery-versus-rest detection may reflect task engagement, not imagery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Benchmarking single-subject detectability of cognitive event-related potentials in healthy controls and minimally conscious state patientsmedRxiv · 2026
- Decoding sequence auditory expectations for clinical diagnostic and prognostic assessment of prolonged disorders of consciousness.Journal of neural engineering · 2026
- Cognitive Motor Dissociation in Disorders of Consciousness: An Individual Participant Data Meta‐AnalysisEuropean Journal of Neurology · 2026
- Prediction of emergence from the minimally conscious state at 6 months using acute-phase clinical and event-related potential indicators in patients with prolonged disorders of consciousness: a single-center retrospective cohort study.Frontiers in neurology · 2026
- Continuous Versus Short EEG After Ischemic Stroke: What cEEG Adds for Detecting Abnormalities and Predicting Post‐Stroke EpilepsyAnnals of Neurology · 2026
- Assessing consciousness by near-nerve electrostimulation in intensive rehabilitation.Journal of neural engineering · 2026