Standardisation Challenges in ELISA-Based Quantification of Equine Chorionic Gonadotropin (eCG/PMSG)
P. Mishchenko, R. M. Martinez, T. Buch, M. Loesle
Key points
From the paper's conclusion- These findings demonstrate that quantitative results obtained with commercially available PMSG ELISAs are not necessarily comparable and may be strongly influenced by calibration-material composition, assay format, and matrix effects.
Abstract
Equine chorionic gonadotropin (eCG/PMSG) is widely used for female-cycle synchronization and estrus induction in livestock and in biomedical research, where reliable quantitative assessment is increasingly important. However, its structural and glycosylation heterogeneity complicates antibody-based measurement and assay standardization. This Technical Note evaluated six commercially available quantitative PMSG ELISA kits representing three distinct analytical profile groups. Kit-provided calibration standards were characterized by Western blotting, Coomassie staining, and LC-MS/MS, while quantitative performance was assessed using serial dilutions of two commercial PMSG preparations. DRG, Creative Diagnostics, and Demeditec showed similar calibration-standard profiles and concentration-dependent responses, although measured concentrations were consistently below nominal values. Biomatik and MyBiosource displayed closely related analytical profiles but little meaningful concentration-dependent response, whereas Krishgen measurements remained within a narrow range despite changes in nominal PMSG input. The calibration standards differed substantially in protein composition, and no eCG-derived peptides were identified by LC-MS/MS under the conditions used. These findings demonstrate that quantitative results obtained with commercially available PMSG ELISAs are not necessarily comparable and may be strongly influenced by calibration-material composition, assay format, and matrix effects. The findings highlight the limitations of current quantitative PMSG assays and the need for a well-characterized, commutable reference material, together with assay-specific validation of dilution parallelism and analyte recovery, to improve the reliability and comparability of eCG/PMSG measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Critical comparison of ELISA kits for CGRP measurements in migraine.Headache · 2026
- A-160 Estradiol Measurement in Patients Receiving Exogenous Estradiol Differs by Route of Administration and Immunoassay PlatformClinical Chemistry · 2026
- Assessing measurement uncertainty at laboratory network scale and its impact on diagnostic performance in the absence of a gold standard: application to ELISA tests for Coxiella burnetii in ruminantsbioRxiv · 2026
- Evaluation of a commercial multiplex immunoassay for assessing uterine inflammation in mares susceptible to persistent breeding-induced endometritis.Veterinary immunology and immunopathology · 2026
- Development of a sandwich ELISA for recombinant feline GM-CSF and determination of its serum half-life.Frontiers in veterinary science · 2026
- 53 Optimal Exogenous Estradiol Dosing Varies by Route of Administration and Assay platformAmerican Journal of Clinical Pathology · 2026