Measurement-Dependent Parameter Recoverability in Neural Cardiovascular LPN Inference.
Nanlong Sun, Yue Li, Sanjian Zhang, Yurui Chen, Lei Shi
Key points
From the paper's conclusion- These findings demonstrate that accurate reconstruction of observed hemodynamics does not necessarily imply accurate recovery of the underlying LPN parameters, highlighting the importance of assessing parameter recoverability and predictive uncertainty when physiologically meaningful parameter estimates are sought.
Abstract
Estimating cardiovascular lumped-parameter network (LPN) parameters from limited hemodynamic observations is a potentially non-unique inverse problem in cardiovascular model personalization. We investigated how parameter recoverability depends on measurement availability and noise, and whether poor recovery reflects limitations of neural inference or insufficient observational information. We developed Mada (measurement-availability and difficulty-aware), a probabilistic neural framework that provides parameter estimates and predictive uncertainty under incomplete observations. Using a closed-loop, four-chamber cardiovascular LPN with time-varying elastance, we generated a synthetic population of 650,000 cases comprising 20 chamber-mechanics and vascular parameters and up to 30 hemodynamic and timing observations. Under complete observations, Mada achieved macro R 2 = 0.862, maintaining competitive accuracy across neural baselines while providing parameter-specific uncertainty. Recoverability varied substantially across parameters, with atrial active elastances remaining particularly difficult. For mask-aware Mada, macro R 2 ranged from 0.066 with basic clinical measurements to 0.751 with a rich clinical set and 0.842 with all measurements, while uncertainty generally increased as informative measurements were removed. Bounded direct optimization achieved substantially smaller hemodynamic residuals but did not consistently recover the generating parameters. Complementary profile and local-sensitivity analyses revealed case-specific parameter compensation and weak observational directions, while target-specific fine-tuning offered little improvement for difficult atrial parameters. Increasing measurement noise degraded both parameter recovery and predictive-interval coverage, and similar trends were observed with a simpler probabilistic ResMLP. These findings demonstrate that accurate reconstruction of observed hemodynamics does not necessarily imply accurate recovery of the underlying LPN parameters, highlighting the importance of assessing parameter recoverability and predictive uncertainty when physiologically meaningful parameter estimates are sought.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Dual-Output Physiology-Informed Neural Network Architecture for Continuous Cuffless Blood Pressure Waveform Estimation: A Proof‑of‑ConceptArtery Research · 2026
- Augmentation of cardiovascular flow measurements with generative diffusion modelsarXiv · 2026
- PUNCH: Physics-informed uncertainty-aware network for coronary hemodynamics.Medical image analysis · 2026
- Continuous Cuffless Blood Pressure Estimation Using a Multimodal Conv1D-LSTM Architecture and the SOUNDI® Wearable Device.Biosensors · 2026
- Evolutionary Optimization of Extended Kalman Filter Hyperparameters for Adaptive Data-Driven ABP Prediction Framework Inspired by Cardiovascular Digital-Twin PrinciplesAlgorithms · 2026
- Incremental Discrimination of a Logistic-Regression Model Using Physiological and Missingness Predictors Beyond Six-Hour Mean Arterial Pressure for Sustained Hypotension: A FHIR-Based Pilot StudyBioMedInformatics · 2026