Automated Versus Conventional Annular Suturing in Totally Endoscopic Aortic Valve and Ascending Aorta Replacement: A Prospective Randomized Trial
M. Hamiko, J. Rogaczewski, S. Salamate, A. Bayram, F. Piekarski, K. Eghbalzadeh, M. Silaschi, J. Kruse,
Key points
From the paper's conclusion- Methods Between August 2023 and February 2026, 86 patients undergoing totally endoscopic AVR with concomitant AAR via right anterior minithoracotomy (RAMT) were randomized 1:1 to automated annular (RAM group; n=43) or conventional suturing (conventional group; n=43) in this single-center trial.
Abstract
Background Totally endoscopic aortic valve replacement (AVR) combined with ascending aorta replacement (AAR) remains technically demanding, with prolonged CPB and ischemic times. Annular suturing is a principal technical limitation; automated devices aim to simplify this step and improve efficiency. This study compared early clinical outcomes between automated and conventional annular suturing in totally endoscopic AVR with concomitant AAR. Methods Between August 2023 and February 2026, 86 patients undergoing totally endoscopic AVR with concomitant AAR via right anterior minithoracotomy (RAMT) were randomized 1:1 to automated annular (RAM group; n=43) or conventional suturing (conventional group; n=43) in this single-center trial. Primary endpoints were technical success and procedural times; secondary endpoints included complications and 30-day mortality. Results Baseline characteristics were comparable, bicuspid aortic valve morphology was more frequent in the RAM group (74.4% vs. 53.5%; P = 0.043). Automated suturing was associated with shorter median procedure (120.8 vs. 144.0 minutes; P = 0.004), CPB (90.0 vs. 105.0 minutes; P = 0.005), and aortic cross-clamp times (62.0 vs. 74.0 minutes; P = 0.003), respectively. No stroke, conversion to sternotomy, paravalvular leakage, or 30-day mortality occurred in either group. Hospital stay was shorter with automated suturing (6.0 vs. 7.0 days; P = 0.037), while total treatment cost, accounting for incremental device cost, did not differ significantly (P = 0.421). Conclusions Automated annular suturing appears to be a safe, efficient alternative to conventional suturing in totally endoscopic AVR with AAR, associated with reduced operative and ischemic times and shorter hospital stay without compromising early outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility, Technical Safety, and Early Clinical Experience with an Automated Annular Suturing Device in Minimally Invasive Valve Replacement.Journal of clinical medicine · 2026
- Robotic mini-thoracotomy approach to aortic valve and ascending aorta replacement.Multimedia manual of cardiothoracic surgery : MMCTS · 2026
- Totally endoscopic aortic valve replacement for quadricuspid aortic valve.Multimedia manual of cardiothoracic surgery : MMCTS · 2026
- Minimally invasive anaortic quadruple and quintuple coronary artery bypass grafting: Feasibility and early outcomes of automated titanium suture fastener - a case series.Science progress · 2026
- Aortic valve replacement and concomitant coronary artery bypass grafting: technical considerations in the era of sutureless and rapid-deployment aortic valves.Expert review of cardiovascular therapy · 2026
- Right Anterior Thoracotomy Aortic Valve Replacement: Technique and Early Outcomes in 156 PatientsHearts · 2026