Post-implantation 3-T MRI in patients with an epicranial stimulation device: image quality and deep learning-based electrode reconstruction
N. Schwaderlapp, A. Barghoorn, S. Kalousios, M. Duempelmann, E. Martinez-Lizana, N. Zabler, B. Steinhoff, V. Dinkelacker,
Key points
From the paper's conclusion- We evaluated structural and functional MRI at 3 T in five patients with an implanted EASEE focal cortex stimulation system and assessed MRI-only electrode reconstruction.
Abstract
We evaluated structural and functional MRI at 3 T in five patients with an implanted EASEE focal cortex stimulation system and assessed MRI-only electrode reconstruction. Image quality was evaluated visually and by comparing implant-centered and control regions using structural GM/WM signal ratios, GE-EPI signal intensity, T2*, and relative off-resonance. A deep learning pipeline trained exclusively on synthetic data estimated electrode position from T1-weighted MPRAGE images. Structural and functional acquisitions were completed in all patients without scan-related adverse events. Structural images showed clear intracranial anatomy beneath the implant without visually apparent local signal loss or distortion. GE-EPI reference images and derived maps showed no consistent local disturbance corresponding to the electrode. GE-EPI signal was numerically lower in implant-centered regions, but no imaging metric differed significantly between regions (all p > 0.05). Electrode reconstructions were anatomically plausible in all patients, with patient-specific median central electrode-to-cortical gray-matter distances ranging from 9 to 20 mm. These findings demonstrate the feasibility of post-implantation structural and functional MRI and MRI-only estimation of electrode-cortex geometry, although localization accuracy remains unvalidated. This combination provides a basis for future studies integrating patient-specific electrode geometry, electric-field modeling, and functional connectivity analyses in focal cortex stimulation with the EASEE system.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electroencephalography for Radiation-Free Orientation Estimation of Directional Deep Brain Stimulation LeadsbioRxiv · 2026
- Standardized Localization of Intraoperative Direct Electrical Stimulation Sites in Awake Brain Surgery Using MRI-Based 3D Cortical Mapping.Brain sciences · 2026
- Head-only MRI of Deep Brain Stimulation devices at 0.5 T: Patient-derived approaches for estimating radiofrequency heating.NeuroImage · 2026
- RF-EMF response modeling of implantable medical electrodes under 1.5T and 3T MRI exposure using a lumped element model approach.Physics in medicine and biology · 2026
- Mid-field MRI with cochlear implants: a healthy volunteer study of magnet displacement, pressure perception, and temporal bone imagingBMC Medical Imaging · 2026
- Physics-informed neural operators for rapid electric field prediction in transcranial magnetic stimulation of healthy and tumor subjectsScientific Reports · 2026