Quantized TotalSegmentator for Fast Abdominal Organ Segmentation on CPUs
J. H. Lee
Key points
From the paper's conclusion- TS-Portable achieved noninferior abdominal organ segmentation accuracy compared with the reference implementation while running faster on a workstation CPU than the reference on a GPU.
Abstract
BACKGROUND. TotalSegmentator is designed for a graphics processing unit (GPU), runs slowly on a central processing unit (CPU), and depends on Python, limiting CPU-only clinical deployment. OBJECTIVE. The purpose of this study was to evaluate whether TS-Portable, a self-contained CPU executable running 8-bit integer (INT8)-quantized TotalSegmentator models, is noninferior to the reference implementation across 15 abdominal organs in an external multicenter cohort, quantify CPU-only runtime, and demonstrate spleen volumetry on a picture archiving and communication system (PACS) reading station. METHODS. This retrospective study compared TS-Portable with the reference Python implementation on 100 external multicenter CT scans and 28 chronic liver disease series. Per-case mean Dice similarity coefficient (DSC) and 3-mm normalized surface distance (NSD@3 mm) across 15 organs (1.5-mm resolution) and spleen-only mode were tested against a 0.01 noninferiority margin (paired bootstrap 95% CIs). Workstation and PACS runtimes were recorded; spleen volumes were compared via Lin's concordance correlation coefficient (CCC) and Bland-Altman analysis. RESULTS. The external cohort included 100 patients (53 men, 47 women; mean age, 53 {+/-} 16 [SD] years). Across 15 organs, TS-Portable was noninferior for mean DSC (difference, 0.00017; 95% CI, 0.00003 to 0.00031; p < .001) and NSD@3 mm (difference, 0.00015; 95% CI, -0.00002 to 0.00031; p < .001) and in spleen-only mode (both p < .001). Workstation 1.5-mm median runtime was 48.0 seconds for TS-Portable on CPU versus 342.5 seconds on CPU (ratio, 7.14) and 61.5 seconds on GPU (ratio, 1.28) for the reference. On PACS, CPU spleen volumetry took 5.8 versus 43.4 seconds, agreeing with the reference (CCC, 0.9999; bias, 0.2%; 95% limits of agreement, -7.2% to 7.6%) and manual contours (CCC, 0.989; bias, -6.8%). In 28 chronic liver disease series, TS-Portable ran from DICOM in 6.5 seconds (median), agreeing with the reference (CCC, 0.99999) and manual contours (CCC, 0.992; bias, -3.4%). CONCLUSION. TS-Portable achieved noninferior abdominal organ segmentation accuracy compared with the reference implementation while running faster on a workstation CPU than the reference on a GPU. CLINICAL IMPACT. Self-contained deployment enables fast multiorgan segmentation on CPU-only computers and spleen volumetry within seconds on a standard reading station, without dedicated GPUs or software installation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FlashSegmentator: High-Throughput TotalSegmentator Inference without Loss of AccuracyarXiv · 2026
- Multifaceted validation of TotalSegmentator performance in abdominal organ segmentation on CT scans integrated in clinical-grade PACSEuropean Journal of Radiology Artificial Intelligence · 2026
- Segment Everything, Materialize Nothing: Exact Streaming Inference for Many-Class 3D SegmentationarXiv · 2026
- ReSeg: Retraining-free segmentation of abdominal organs via generalizable semantic representation learningarXiv · 2026
- Retention-Constrained Post-Training Quantization of Cellpose-SAM for Stem Cell MicroscopyarXiv · 2026
- PR-SDMLP: progressive cross-scale refinement with bidirectional shifted dynamic MLPs for jaw cyst segmentation in CBCT scansFrontiers in Bioengineering and Biotechnology · 2026