From the paper's conclusion- We assumed the pulsation artifact was predominantly present in the left liver lobe in the b800 images.
Abstract
Background: Liver diffusion-weighted imaging (DWI) often shows signal loss in the left lobe due to cardiac pulsation, known as the pulsation artifact. Purpose: This study was conducted to turn this bug into a feature. We hypothesized that the pulsation artifact, caused by mechanically transmitted waves, is influenced by tissue stiffness and, thereby, indicative of cirrhosis in the left liver lobe. Thus, we evaluated the potential of DWI pulsation artifacts to detect liver cirrhosis. Study type: This study included both retrospective patients and prospective healthy volunteers. Study population: Thirteen healthy volunteers, 16 patients with cirrhosis (Ishak 5 or 6), and three patients without cirrhosis (Ishak 0, 1, or 2) were included. Field Strength/Sequence: Imaging was performed at 1.5 T and 3 T using echoplanar DWI of the liver with two b-values, b50 = 50 s/mm2 and b800 = 800 s/mm2. Assessment: After manual segmentation of the left and right liver lobes, 18 first-order features were extracted from b50 and b800 images. We assumed the pulsation artifact was predominantly present in the left liver lobe in the b800 images. Thus, we computed the ratios of the intensity-normalized b800 features obtained from the left and right liver lobes. Additionally, we performed an intensity normalization to address the sometimes different signal intensities of left and right liver lobe. Then, we conducted a receiver operating characteristic (ROC) analysis to differentiate cirrhotic from non- cirrhotic livers. Statistical tests: ROC analysis and leave-one-out bootstrapping were applied, both yielding area under the curve (AUC) values. Results: Left liver pulsation artifacts were more pronounced in non-cirrhotic livers and largely absent in cirrhotic livers. The first quartile feature, i.e. the first quartile of the normalized signal, best distinguished cirrhotic from non-cirrhotic livers (AUC = 0.95; 95% confidence interval 0.87-1.00). Data conclusion: The left liver DWI pulsation artifact reflects liver stiffness and could serve as a simple, intrinsic marker of liver cirrhosis. Analysis of the signal magnitude can differentiate cirrhotic from non-cirrhotic livers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diffusion-weighted Imaging of the Liver: Primed for New BusinessRadiology · 2026
- Quantitative evaluation of shear stiffness and the apparent diffusion coefficient using anthropomorphic multi-stiffness liver phantoms under static and motion conditions.Magnetic resonance imaging · 2026
- The worth of diffusion-weighted imaging for quantifying liver iron concentration in transfusion-dependent thalassemia patients.Acta radiologica (Stockholm, Sweden : 1987) · 2026
- Assessment of Liver Fibrosis Using the Coefficient of Variation on Gadoxetic Acid-Enhanced Hepatobiliary Phase MR Imaging: A Prospective Multicenter Study.Journal of clinical medicine · 2026
- Assessment of Liver Stiffness in a Rat Model of Type 2 Diabetes Using Shear Wave Elastography.Diagnostics (Basel, Switzerland) · 2026
- Ultrasound Shear Wave Elastography for Liver Stiffness and Attenuation Imaging for Liver Steatosis in Patients With Metabolic Dysfunction-Associated Fatty Liver Disease.Medical science monitor : international medical journal of experimental and clinical research · 2026