Diagnostic Accuracy of Fine Needle Aspiration Cytology in Thyroid Diseases: Comparison with Histopathological Findings in Hawassa, Ethiopia
A. M. Nisro, T. T. Geremew, A. K. Tadele, B. D. Fenta, G. G. Engida, F. Y. Lukas, T. G. Tesgera, A. T. Alem
Key points
From the paper's conclusion- The accuracy of fine needle aspiration cytology in differentiating benign from malignant thyroid lesions was 93.1%.
Abstract
Introduction: Thyroid diseases are major health problems and among the most common endocrine disorders worldwide, including in Ethiopia. They are characterized by alterations in hormone secretion, enlargement of the thyroid gland, or both. Fine needle aspiration cytology is an important initial screening tool, and histopathologic examination is essential for the definitive diagnosis of thyroid disease. This study aimed to compare the diagnostic accuracy of fine needle aspiration cytology with histopathology in identifying thyroid diseases. Methods: A cross-sectional study was conducted at three health facilities in Hawassa City, Ethiopia, involving 304 patients who underwent both thyroid fine needle aspiration cytology and histopathologic examination of the same site between 30th October 2024 and 29th October 2025. FNAC results were classified using the Bethesda system, with histopathology as the gold standard. Data were entered into Kobo Toolbox, exported to SPSS version 27, and analyzed using cross-tabulation and chi-square ({chi}{superscript 2}) tests to determine diagnostic accuracy. Result: 304 patient records were included in the study. The fine needle aspiration cytology was determinate/diagnostic in 81.6% of cases. The study revealed the sensitivity and specificity of fine needle aspiration cytology to be 88.2% (CI 77.6-95.1%) and 94.4% (CI 90.6-97.1%), respectively. The false negative and false positive rates in this study were 2.4% and 4.4%, respectively. The positive predictive value was 80.3% (CI 68.7-89.3%), and the negative predictive value was 96.8% (CI 93.8-98.7%). The accuracy of fine needle aspiration cytology in differentiating benign from malignant thyroid lesions was 93.1%. Conclusion: FNAC demonstrated strong agreement with histopathology and remains a reliable, cost-effective first-line diagnostic tool for thyroid disease, particularly in resource-limited settings. Strengthening sample handling, ultrasound guidance, and adherence to Bethesda criteria may further improve diagnostic precision
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cytomorphological spectrum of thyroid lesions using the Bethesda system: A retrospective study.Bioinformation · 2026
- Comparative Diagnostic Accuracy of Fine-Needle Aspiration Cytology Versus Fine-Needle Non-aspiration Cytology in Thyroid Lesions: A Cross-Sectional Study.Cureus · 2026
- Multimodal Diagnostic Cross-Check: A Correlative Study of Fine-Needle Aspiration Cytology, Ultrasonography, Thyroid Profile, and Histopathology in Thyroid Swellings.Cureus · 2026
- Diagnostic Performance of the International Academy of Cytology Yokohama System for Reporting Breast Fine-Needle Aspirates: A Cytology-Histopathology Correlation Study From Central India.Cureus · 2026
- Association Between Sonographic Calcification Phenotype and Nondiagnostic Thyroid Fine-Needle Aspiration.Cytopathology : official journal of the British Society for Clinical Cytology · 2026
- A serum thyroid hormone metabolite test for molecular diagnostic evaluation of thyroid nodulesmedRxiv · 2026