Trust, but Verify: Epistemic Uncertainty-Gated Pseudo-Labeling for Safer Semi-Supervised Malaria Screening
A. Kumar, A. Anand, L. Chhetri
Key points
From the paper's conclusion- We trained a ResNet-18 on the public Malaria Cell Images dataset (27,558 cell images; 70:10:20 split) using labels for only 20% of the training images.
Abstract
Background. Deep learning could make malaria microscopy more accessible in low-resource settings, but training it usually needs thousands of expert-labeled images. Semi-supervised learning (SSL) reduces this need by also learning from unlabeled images. However, methods such as FixMatch accept pseudo-labels using a fixed confidence threshold, and lowering that threshold to use more data can teach the model to make confident mistakes. These silent failures are dangerous because they are never flagged for expert review. Methods. We added an uncertainty check to SSL pseudo-labeling. Each unlabeled image is passed through the model ten times with Monte Carlo dropout active; its pseudo-label is used only if the normalized predictive entropy of the averaged prediction is below 0.2, and it is then weighted by a sigmoid function of model confidence. We trained a ResNet-18 on the public Malaria Cell Images dataset (27,558 cell images; 70:10:20 split) using labels for only 20% of the training images. Over six random seeds, we compared the method with a supervised baseline and with FixMatch at thresholds of 0.95 and 0.80, measuring accuracy, AUC and silent failure rate (SFR), the share of predictions that are wrong despite confidence above 0.95. Results. Compared with FixMatch at a threshold of 0.80, our method lowered the mean SFR from 2.28% to 1.52%, a 33.2% relative reduction (paired t-test, t = 4.29, p = 0.0078), and the SFR was lower in all six runs. Accuracy (96.6% vs. 96.4%) and AUC (0.991 for both) were unchanged. The mean SFR was also below that of FixMatch at 0.95 (1.97%) and of the supervised baseline (2.01%). Conclusions. Checking epistemic uncertainty before accepting pseudo-labels reduced confident errors in semi-supervised malaria cell classification without lowering accuracy. Patient-level and external validation on whole-slide images are still needed before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep learning-assisted malaria microscopy with sensitivity-aware threshold optimization.Frontiers in medicine · 2026
- Rigorous Evaluation of Large Language Models for Malaria Drug Discovery: Trade-offs in Performance, Scale, and Resource UtilityarXiv · 2026
- Explainable AI for Malaria Diagnosis: Comparative Analysis of ML Models Using Random Forest Feature Selection and SHAP InterpretabilityAsian Journal of Research in Computer Science · 2026
- Explainable Deep Learning for Malaria Parasite Detection and Species Differentiation in Thick Blood Smear Images: A Pilot Feasibility StudyarXiv · 2026
- MalarIA: A Modular AI-Powered Web Platform for Automated Plasmodium Species Classification from Blood Smear Microscopy.Tropical medicine and infectious disease · 2026
- Deep Learning-Based Malaria Parasite Image Classification on Real Microscopy Data.Infectious disease reports · 2026