In Silico Metrological Assessment of 2D ROI Sampling Error Versus Whole-Organ 3D Volumetric CT Attenuation in Hepatic Steatosis: A Multicenter Monte Carlo Simulation on 971 Scans
F. Zemmour
Key points
From the paper's conclusion- Purpose: To quantify the sampling error of conventional 2D regions of interest (ROIs) compared with whole-organ 3D volumetric CT attenuation for opportunistic hepatic steatosis screening, and to evaluate its dependency on intraparenchymal spatial heterogeneity.
Abstract
Purpose: To quantify the sampling error of conventional 2D regions of interest (ROIs) compared with whole-organ 3D volumetric CT attenuation for opportunistic hepatic steatosis screening, and to evaluate its dependency on intraparenchymal spatial heterogeneity. Materials and Methods: In this retrospective computational study (CLAIM-compliant), 971 abdominal CT scans were analyzed across a multicenter derivation cohort (TotalSegmentator v2, n = 841) and an external validation cohort (Medical Segmentation Decathlon Task03, n = 130). Automated 3D liver segmentation was performed using nnU-Net, followed by an 8-mm spherical 3D erosion to eliminate peripheral partial volume effects and major hilar vessels. Three clinical sampling paradigms (1, 3, and 5 axial 2D ROIs of 15 mm diameter) were modeled through 500 stochastic Monte Carlo iterations per scan (485,500 total simulations). Absolute sampling error (|Delta HU| = |HU_ROI - HU_3D|) and diagnostic misclassification rates at the standard <= 40 HU steatosis threshold were computed. Results: In the derivation cohort, the conventional 3-ROI approach yielded a mean absolute error of 6.61 +/- 7.83 HU (median: 2.92 HU), significantly underperforming compared to the 5-ROI strategy (5.21 +/- 6.00 HU; Wilcoxon paired test, p < 0.001) but improving on the single-ROI approach (11.32 +/- 14.16 HU; p < 0.001). Sampling error correlated strongly with parenchymal spatial heterogeneity (Pearson r = 0.850, 95% CI: [0.830-0.868], p < 0.001). In borderline attenuation zones (35-45 HU), diagnostic misclassification reached 45.2% in heterogeneous livers. Findings were corroborated on external validation, confirming the reproducible decay of sampling error (|Delta HU| = 7.38 HU for 1 ROI vs. 5.14 HU for 3 ROI, p < 0.001). Conclusion: Manual 2D ROI sampling exhibits an intrinsic metrological uncertainty exceeding clinically relevant thresholds (5 HU) in heterogeneous livers, misclassifying nearly half of borderline cases. Opportunistic screening requires fully automated 3D volumetric extraction embedded into clinical PACS workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of CT-detected hepatic steatosis in adults between two Middle Eastern centers: a retrospective dual-center studyEgyptian Journal of Radiology and Nuclear Medicine · 2026
- Spatial characterization of intrahepatic fat deposition across steatotic liver disease subcategories: a multicenter studyBMC Medicine · 2026
- Opportunistic Detection of Hepatic Steatosis Using Postcontrast Liver Attenuation at Coronary CT Angiography.Radiology. Cardiothoracic imaging · 2026
- Semi-automated CT attenuation measurement for MASLD: volumetric versus peripheral-ROI methods.BMC medical imaging · 2026
- Strategy to Improve Diagnostic Performance of Hepatic Steatosis Grading Using Ultrasound: Combination of Qualitative and Quantitative Approaches.Medicina (Kaunas, Lithuania) · 2026
- Hepatorenal index and an exploratory combined model for identifying moderate-to-severe histologic steatosis in patients with liver injury of undetermined etiology.Frontiers in medicine · 2026