Conductive Hydrogels as a Medium for Shapeable Catheter Ablation Electrodes
D. Bernard, L. Jaworski, M. John, A. Post, A. Nkansah, D. Bashe, M.-H. Sung, E. Cosgriff Hernandez,
Key points
From the paper's conclusion- Moldable, conductivity-tunable hydrogels shape RF lesions and may improve ablation safety, supporting evaluation for contiguous or linear lesion sets and ablation near sensitive structures.
Abstract
BACKGROUND: Radiofrequency catheter ablation (RFCA) uses rigid metallic electrodes whose fixed geometry limits tissue contact, lesion continuity, and safe energy delivery near vulnerable structures. We evaluated a moldable, tissue-conforming conductive hydrogel as an RFCA electrode ex vivo. METHODS: Poly(ether urethane diacrylamide) hydrogels with saline-tuned conductivity were molded into plugs, disks, and bars and affixed to an irrigated 8-Fr catheter. Ablations were performed on excised porcine tissue in circulated saline at 37 C under fixed contact force and irrigation. Lesion geometry, intramural temperatures, and steam pops were compared with bare-metal (BM) electrodes and size-matched metallic analogs; an atrioesophageal stack model assessed collateral injury. Lesions were delineated using triphenyltetrazolium chloride staining. RESULTS: Hydrogel bars produced wide, ellipsoidal lesions (width 10.51 {+/-} 1.40 versus 8.71 {+/-} 1.65 mm for BM; P=0.031; aspect ratio 1.72); size-matched metal bars produced none. Hydrogel disks produced lesions statistically indistinguishable from BM in depth (4.54 {+/-} 0.90 versus 4.84 {+/-} 0.55 mm) and width (9.47 {+/-} 0.89 versus 11.41 {+/-} 2.39 mm), whereas metal disks produced significantly shallower lesions (2.30 {+/-} 1.70 mm; P=0.015 versus BM). In the atrioesophageal model, hydrogel plugs achieved transmural atrial lesions with a reduced esophageal lumen temperature (56.33 {+/-} 3.80 versus 61.30 {+/-} 5.14 C; P=0.046), total lesion depth (4.03 {+/-} 1.25 versus 7.58 {+/-} 0.78 mm; P<0.001), and esophageal lesion width (3.05 {+/-} 2.35 versus 8.70 {+/-} 2.69 mm; P<0.001) compared with BM. Hydrogel electrodes reduced steam-pop risk (relative risk 0.34; 95% CI 0.13-0.88). Plug characterization confirmed saline-dependent conductivity and attenuated energy delivery, with lower subsurface peak temperatures and shallower lesions than BM. CONCLUSIONS: Moldable, conductivity-tunable hydrogels shape RF lesions and may improve ablation safety, supporting evaluation for contiguous or linear lesion sets and ablation near sensitive structures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Facile and robust integration of functional hydrogels into micropillar-structured elastomer platforms for stable cardiac bioelectronicsScience Advances · 2026
- Uniform and Complete Irreversible Electroporation on Gastric Mucosa Enabled by Sintered Silver Hydrogel.Cyborg and bionic systems (Washington, D.C.) · 2026
- Thermo-responsive, on-demand adhesive and tissue-conformal hydrogel electrodes for organ repair and brain-computer interfacesMaterials Today Bio · 2025
- Self-Growing Conductive Hydrogels Establish Volumetric Biointerfaces for Cardiac Conduction Restoration.Advanced materials (Deerfield Beach, Fla.) · 2026
- Injectable Conductive Hydrogel Patch with Spatiotemporally Tailored Asymmetric Adhesion for Myocardial Infarction RepairAdvanced Materials · 2025
- A Skin-Compatible Carboxymethyl Cellulose-Reinforced Gelatin Hydrogel with High Adhesion and Low Impedance for High-Fidelity Electrocardiogram Monitoring.ACS applied materials & interfaces · 2026