Estimating Sensitivity from Tandem Colonoscopy Meta-analyses.
Pedro Nascimento de Lima, Rachel B Issaka, Carolyn M Rutter
Key points
From the paper's conclusion- We introduce Bayesian and frequentist approaches to estimate white-light colonoscopy (WLC) sensitivity from tandem colonoscopy meta-analyses.
Abstract
BACKGROUND: Tandem colonoscopy meta-analyses estimate adenoma miss rates, which have been used as a proxy for colonoscopy sensitivity. Doing so overstates sensitivity because it ignores lesions missed by both exams. METHODS: We introduce Bayesian and frequentist approaches to estimate white-light colonoscopy (WLC) sensitivity from tandem colonoscopy meta-analyses. Neither approach assumes that the second colonoscopy is perfect. We apply both approaches to reanalyze data from a recent tandem colonoscopy meta-analysis, overall and across ten subgroups. Sensitivity analyses assess how assumptions about the relative performance of enhanced colonoscopy versus WLC affect estimates. RESULTS: Under our Baseline specification, overall WLC sensitivity estimated by the Bayesian model was 0.54 [0.41, 0.63] (posterior mean and 95% credible interval). Sensitivity rose with lesion size: 0.49 [0.35, 0.60] for 1-5 mm adenomas, 0.64 [0.43, 0.78] for 6-9 mm adenomas and 0.84 [0.70, 0.93] for lesions 10 mm or larger. The frequentist plausible range encompassed the Bayesian estimate. The model-implied miss rate (0.35 [0.30, 0.40]) matched the original meta-analysis estimate and was stable across prior specifications. Assuming enhanced colonoscopy was perfect overstated overall sensitivity by 0.12 [0.06, 0.20]. LIMITATIONS: Tandem colonoscopy data identify the miss rate but not WLC sensitivity, so estimates depend on an external assumption about the relative performance of enhanced colonoscopy versus WLC. As a result, WLC sensitivity estimates varied with the prior specification, especially for small and flat adenomas. CONCLUSIONS: WLC sensitivity may be meaningfully lower than previously assumed in CRC screening cost-effectiveness analyses. Modelers should use colonoscopy sensitivity estimates that do not assume a second colonoscopy exam is perfect.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bias in Meta-Analytic Modeling of Surrogate Endpoints in Cancer Screening Trials.Statistics in medicine · 2026
- Bootstrap Calibration of Likelihood-Ratio Inference for the Hypergeometric-Normal Random-Effects Model in Rare-Event Meta-Analysis.Statistics in medicine · 2026
- Evaluating adenoma detection and miss rates in tandem colonoscopy: Limitations of surrogate quality indicators.Advances in clinical and experimental medicine : official organ Wroclaw Medical University · 2026
- Improving the selection-function-based sensitivity analysis for publication bias with restricted maximum likelihoodarXiv · 2026
- Structural equation modelling--based meta-analytic model for diagnostic test accuracy studiesarXiv · 2026
- Random-effects meta-analysis via generalized linear mixed models: A Bartlett-corrected approach for few studies.Biometrics · 2026