CryoMV: Structure-Prior-Guided Modeling and Real-Particle Validation of Continuous Conformational Transitions in Cryo-EM
F. Li, H. Dong, S. Tang, X. Wang, C. Zhang, C. Ji, R. Han, F. Zhang,
Key points
From the paper's conclusion- Introduced cryoMV, a framework that integrates structure-prior-guided modeling with real-particle validation for continuous conformational transitions using reference density maps and motion priors.
- On EMPIAR-10516 and EMPIAR-10345, cryoMV achieves excellent performance in terms of robustness, verifiability, and reconstruction resolution.
- By incorporating structure-prior modeling and evidence from the raw particles, cryoMV offers an explicit mechanism for assessing whether generated conformations are supported by experimental data.
Abstract
Continuous protein conformations are essential for understanding fundamental biological processes and supporting drug discovery. Although cryo-EM can resolve individual states at high resolution, recovering continuous heterogeneity from 2D particle images remains challenging. High noise, motion blur, and limited structural priors make it difficult to accurately generate and validate high-resolution continuous conformations using raw particle data. Here, we introduce cryoMV, a framework that integrates structure-prior-guided modeling with real-particle validation for continuous conformational transitions. CryoMV uses reference density maps to establish structural anchors and motion priors, models candidate transition paths between selected conformations, and transfers the learned representation to raw 2D cryo-EM particle images. Each candidate conformation is subsequently evaluated using the estimated particle poses and contrast transfer functions. Supported conformations are reconstructed through raw particle back-projection and assessed using canonical half-maps and Fourier shell correlation. On EMPIAR-10516 and EMPIAR-10345, cryoMV achieves excellent performance in terms of robustness, verifiability, and reconstruction resolution. By incorporating structure-prior modeling and evidence from the raw particles, cryoMV offers an explicit mechanism for assessing whether generated conformations are supported by experimental data and provides a practical approach to reducing model-induced artifacts in continuous cryo-EM heterogeneity analysis.
Read the paper
Discussion · 1
Science Skim's AI key points, plus readers' public thoughts
- Introduced cryoMV, a framework that integrates structure-prior-guided modeling with real-particle validation for continuous conformational transitions using reference density maps and motion priors.
- On EMPIAR-10516 and EMPIAR-10345, cryoMV achieves excellent performance in terms of robustness, verifiability, and reconstruction resolution.
- By incorporating structure-prior modeling and evidence from the raw particles, cryoMV offers an explicit mechanism for assessing whether generated conformations are supported by experimental data.
Readers' thoughts
No reader thoughts yet.
Related papers
- Learning the Shared Latent Structure of Cryo-EM Inverse ProblemsarXiv · 2026
- cryoWEight: Conformational ensembles from cryo-EM particle images with weighted ensemble simulationsbioRxiv · 2026
- ARCHER: Amortized cross-specimen pose estimation for cryo-electron microscopybioRxiv · 2026
- Fold'EM: Direct atomic structure inference from Cryo-EM particlesarXiv · 2026
- Modeling cryo-EM structures in alternative states with AlphaFold2-based models and density-guided simulationsCommunications Chemistry · 2025
- Ab initio CryoEM maps minimizing preferred orientation problems in heterogeneous mixtures: ReconSIRENbioRxiv · 2026