SystematIc StudY of Patients with atHerosclerotic neUrovascular Stenoses (SISYPHUS): Study Protocol for a Prospective Observational Cohort Evaluating 3D Rotational Angiography and Final Implant Quality in Carotid Stenting
L. S. Cabral, M. V. Wainstein, S. O. Martins, R. Brondani, J. A. Duarte, A. G. De Almeida, A. Dal Pizzol, R. M. Castilhos,
Key points
From the paper's conclusion- Methods: SISYPHUS is a prospective, multicenter observational cohort of 67 patients undergoing elective CAS across three tertiary centers.
Abstract
Background and Purpose: Minor periprocedural ischemic events remain an important limitation of carotid artery stenting (CAS) compared with endarterectomy. Adverse-stent-vessel plaque interactions and in-stent plaque protrusion are proposed as contributing mechanisms. Selective intra-arterial three-dimensional rotational angiography (3DRA) provides high-resolution volumetric imaging directly in the endovascular suite without additional device crossing. Its incremental value for characterizing final implant quality and informing prognosis remains incompletely established. Objectives: We aim to determine whether adding 3DRA to conventional digital subtraction angiography (DSA): (1) improves expert characterization and reproducibility of Final Implant Quality (Imaging Domain); and (2) provides incremental prognostic information for 90-day Textbook Outcome failure beyond baseline clinical risk and conventional DSA (Prognostic Domain). Methods: SISYPHUS is a prospective, multicenter observational cohort of 67 patients undergoing elective CAS across three tertiary centers. Three blinded neuroradiologists will evaluate standardized image packages sequentially under DSA-only and DSA+3DRA conditions. Final Implant Quality will be assessed with a structured 10-item instrument: Q1-Q8 characterize specific findings, Q9 evaluates global implant adequacy (primary imaging variable), and Q10 captures technical image quality. Concealed repeat assessments will be performed in a randomized 17-patient subset for intra-reader reliability. The primary imaging estimand is the within-reader ordinal shift in Q9 after 3DRA is added, modeled with cumulative-link mixed-effects regression. The primary clinical endpoint is 90-day Textbook Outcome failure, integrating early neurological deterioration, major bleeding/procedural complications, stroke, TIA, MI, death, unplanned revascularization, and unplanned readmission within prespecified ascertainment windows. Incremental prognostic performance will be evaluated using nested ridge-penalized logistic regression models (M2 vs M3) with 2,000-resample bootstrap internal validation. Trial Status & Prospective Lock: Recruitment is complete (n=67), while protocol-defined follow-up remains ongoing. The Orthanc/OHIF reader study environment is being implemented; formal reader evaluations have not yet begun. The principal analytical architecture was prospectively locked in the Statistical Analysis Plan (SAP) Version 1.1.1 before formal inspection of reader results and before real-data prognostic model fitting.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Innovative application of pressure gradient measurement in internal carotid stenosis in patients undergoing carotid artery stenting (NOTICE-CAS): study protocol for a randomized, assessor-blinded, parallel-group clinical trialTrials · 2026
- Plaque-Reporting and Data System bei leichter bis mäßiger KarotisstenoseNeuroradiologie Scan · 2026
- Carotid Plaque-RADS: Impact of its ancillary features on improving the detection of symptomatic plaques.European radiology · 2026
- Comparative evaluation of carotid artery stent designs through a strict randomized evidence synthesis and assessment of local vascular responses.Journal of biomaterials applications · 2026
- Feasibility study for 3D quantitative angiography in internal carotid aneurysms using in silico biplane imaging and 3D vascular geometry constraints.Medical image analysis · 2026
- Diameter measurement of tubular structures on CT angiography, 3D rotational angiography, and 2D digital subtraction angiography against caliper ground truth: A phantom study of surrogates for intracranial vessels.medRxiv · 2026