Low-Noise Finite-Bandgap FET Biosensors in the Nonlinear Gouy-Chapman-Stern Region: A Universal Calibration Curve.
Feng Gao, Tyler Moorman, Tiger Haoran Shi, Sizhe Ma, Kai Ni, Satyajyoti Senapati, Hsueh-Chia Chang
Key points
From the paper's conclusion- Using a fully nonlinear Gouy-Chapman-Stern (GCS) theory, a universal calibration curve is derived and shown to collapse the low-noise FET signals for miRNA, extracellular vesicles (EV), and protein, captured either directly or through silica and magnetic nanoparticle charge reporters, over eleven decades of analyte concentration.
Abstract
Finite-bandgap charge-based FET biosensors are known to be insensitive to electronic tunneling noise in the semiconductor and interference from weakly-charged proteins in physiological samples. However, their signal is still corrupted by pH fluctuations and condensing counterions in the bulk electrolyte. Here, we demonstrate that electrolyte noise is screened by the Stern layer beyond the linear Debye-Hückel limit, when the interfacial potential drop is larger than the thermal voltage. Using a fully nonlinear Gouy-Chapman-Stern (GCS) theory, a universal calibration curve is derived and shown to collapse the low-noise FET signals for miRNA, extracellular vesicles (EV), and protein, captured either directly or through silica and magnetic nanoparticle charge reporters, over eleven decades of analyte concentration. The theory involves the dissociation constant K D and a gain parameter χ, which represents the competing effects of the reporter charge and buffer Debye screening that must be large to produce the low-noise GCS condition. The limit of detection (LOD) is shown to be K D /χ, which can be optimized by varying the probe density, charge reporter, and buffer solution. An optimized hybridization buffer then yields χ ∼ 22 (LOD ∼1 pM) for miRNA detection, and multivalent capture reduces K D by four orders of magnitude for EV detection (relative to protein detection) with χ ∼ 34 (LOD ∼10 fM).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Operational Flaws in Field-Effect Transistor (FET)-Based Biosensors: Gate-Leakage Current in Water-Gate FET Devices and Fake Field-Effect Signals from Biomolecular ChargeBiosensors · 2026
- Graphene-Based Chemical Field-Effect Transistors: Impact of Electric Double Layer Model and Quantum Capacitance on Na+ Detection CapabilitiesMicromachines · 2026
- Field-effect transistor biosensors for biomedical applications: material platforms, interfacial engineering, and translational challenges.Mikrochimica acta · 2026
- Biochemical Interface Engineering for Transistor-Based Point-of-Care DiagnosticsAccounts of Chemical Research · 2026
- Active dual-gated graphene transistors for low-noise, drift-stable, and tunable chemical sensingnpj 2D Materials and Applications · 2026
- Engineering Graphene Field-Effect Transistor Biosensors for Disease Biomarkers Detection in Liquid BiopsyACS Nano · 2025