PRISM: Phase-Resolved Isotropic Subtraction Mapping for Automated Multi-Phase CT Digital Subtraction Angiography
R. Rodriguez, R. Ramirez, H. Rathore
Key points
From the paper's conclusion- We present PRISM (Phase-Resolved Isotropic Subtraction Mapping), an open-source automated pipeline that transforms multi-phase CT acquisitions into registered digital subtraction angiography (DSA) volumes with color-coded enhancement maps.
Abstract
Multi-phase contrast-enhanced computed tomography (CT) is the gold standard for renal cell carcinoma (RCC) characterization, yet clinical interpretation relies on subjective visual comparison across phases. We present PRISM (Phase-Resolved Isotropic Subtraction Mapping), an open-source automated pipeline that transforms multi-phase CT acquisitions into registered digital subtraction angiography (DSA) volumes with color-coded enhancement maps. PRISM integrates six sequential processing stages: (1) DICOM loading with automated contrast-phase classification, (2) deep learning-based isotropic interpolation via RIFE, (3) automated kidney segmentation using TotalSegmentator v2, (4) enhancement-based tissue detection, (5) three-step deformable registration (rigid, affine, B-spline) using SimpleITK, and (6) dual-channel digital subtraction visualization. We present a systematic parameter optimization study comprising 200 registrations across five patients and five experiments. Key findings: We identify an efficient registration configuration combining a 40 mm B-spline grid (within 6% of the 30 mm quality optimum at 36% lower computational cost), 5% metric sampling (equivalent quality to 25% at 3.2x speedup), and a single-level multi-resolution pyramid (avoiding the 5.4x overhead of a 4,2 pyramid with no quality benefit); we show that registration quality is effectively independent of interpolation target spacing from 0.5-3.0 mm, enabling a coarse-register/fine-apply strategy that computes the full transform at 3.0 mm (approximately 4 minutes per phase) and applies it to 0.5 mm volumes for high-resolution visualization. We also determine that a 40 HU subtraction noise threshold optimally balances signal-to-noise ratio (2.00) against sensitivity (14.2% enhancing volume retained), with higher thresholds (60-80 HU) favoring specificity and lower thresholds (20 HU) favoring sensitivity.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Vasculature segmentation in 3D hierarchical phase-contrast tomography images of human kidneysNature Communications · 2026
- Every IVUS Frame in Its Place: A Zero-Install Browser Tool for Registering Intravascular Ultrasound to the Coronary Angiogram, and a Path to Angiography-Only Plaque ImagingarXiv · 2026
- Advancing Real-Time Polyp Detection in Colonoscopy Imaging: An Anchor-Free Deep Learning Framework with Adaptive Multi-Scale PerceptionSensors · 2025
- Transformer-based endoscopic polyp detection with structural reparameterization and dynamic upsamplingScientific Reports · 2026
- When Slides Met Scans: Cross-Attention for Renal Cancer PrognosisarXiv · 2026
- MSR-ABC: Complementary Feature Fusion for Clear Cell Renal Cell Carcinoma ClassificationarXiv · 2026