In Vivo K-edge Imaging on a Clinical Dual-source PCCT: Feasibility of Gadolinium Applications in a Porcine Model
M. V. Rybertt, L. P. Liu, P. Sahbaee, G. McClung, M. Mathew, P. B. Noël, A. H. Dhanaliwala
Key points
From the paper's conclusion- Conclusions: In this proof of concept, gadolinium K-edge imaging was feasible on a clinical dual-source PCCT system for dynamic, functional biliary, and dual-contrast applications, supporting further development with improved material-decomposition sensitivity and confirmation in larger studies.
Abstract
Objectives: To evaluate the feasibility of in vivo gadolinium K-edge imaging on a clinical dual-source photon-counting CT (PCCT) system in a porcine model and to assess its performance for dynamic contrast-enhanced imaging, functional biliary imaging, and dual-contrast (bi-phasic) imaging. Materials and Methods: A single healthy Yorkshire-Landrace pig was imaged on a clinical dual-source PCCT system (140 kVp; energy thresholds 20/55/72/90 keV; CTDIvol 12 mGy). Gadolinium K edge material-specific maps were generated with a calibration-based least-squares material decomposition. Three imaging protocols were evaluated for feasibility: (A) contrast dose testing for dynamic imaging with a hepatobiliary-clearing gadolinium contrast agent (0.2 and 0.8 mL/kg); (B) functional biliary imaging with dynamic and delayed acquisitions; and (C) dual-contrast imaging with simultaneous iodine and gadolinium decomposition. Attenuation (HU) and material concentrations (mg/mL) were measured from regions of interest. Results: Gadolinium was quantifiable in material-specific maps at a contrast dose of 0.8 mL/kg (arterial aortic signal, 114 {+/-} 4 HU and 1.4 {+/-} 0.3 mg/mL; delayed bile duct, 111 {+/-} 4 HU and 4.3 {+/-} 0.4 mg/mL). Hepatobiliary excretion was tracked over time, with bile duct gadolinium plateauing near 3.3 mg/mL approximately 15 minutes after injection. In the dual contrast acquisition, arterial gadolinium (2.5 {+/-} 0.7 mg/mL) and portal venous iodine (1.9 {+/-} 0.7 mg/mL) were separated within the liver, and both agents were separated within the ureters. Conclusions: In this proof of concept, gadolinium K-edge imaging was feasible on a clinical dual-source PCCT system for dynamic, functional biliary, and dual-contrast applications, supporting further development with improved material-decomposition sensitivity and confirmation in larger studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- K‐Edge imaging using a clinical dual‐source photon‐counting CT systemJournal of Applied Clinical Medical Physics · 2026
- First evaluation of color K-edge image quality using spectral photon-counting CT combined with two contrast agents: A phantom studyDiagnostic and Interventional Imaging · 2025
- Multi-Contrast Deep-Silicon Photon-Counting CT for Post-Embolization Imaging: A Quantitative Phantom StudymedRxiv · 2026
- Simultaneous pulmonary ventilation and perfusion imaging using spectral photon counting CT with xenon and gadolinium-based agents in combination with color K-edge imagingDiagnostic and Interventional Imaging · 2026
- MRI-Derived Evaluation of Liver Function and Its Extension to K-Edge Photon-Counting CT: Focus on Gadolinium-Based Functional Biliary Imaging.Diagnostics (Basel, Switzerland) · 2026
- Lumen imaging in calcified coronary arteries using high-resolution Gd-enhanced color K-edge imaging with spectral photon-counting CT: a phantom studyEuropean Radiology Experimental · 2026