From the paper's conclusion- Our purpose was to determine the sensitivity of pupillometry using HP Reverb G2 Omnicept virtual reality (VR) headset for detecting anisocoria and relative afferent pupillary defect (RAPD).
Abstract
Purpose: Pupil examination is a routine examination of patients presenting with ophthalmological or neurological symptoms. Our purpose was to determine the sensitivity of pupillometry using HP Reverb G2 Omnicept virtual reality (VR) headset for detecting anisocoria and relative afferent pupillary defect (RAPD). Methods: Twenty-nine patients were included; Group I with asymmetric optic neuropathy (N=21) and Group II with suspected pathological anisocoria (N=8); alongside 19 controls. VR pupillometry consisted of Pupil symmetry test and Swinging light test. Pathological thresholds were established using upper limits of controls. Results were compared with routine pupil exam. Correlations with functional ophthalmological test results were analyzed. Results: RAPD was detected in 16/21 Group 1 patients using both VR pupillometry and standard exam. Remaining 5 had relative afferent pupillary asymmetry (RAPA) within the control range (0.1-0.2 mm). Significant correlation was found between RAPA/RAPD and inter-eye difference in visual acuity and visual field defect (MD) (R=0.58 and 0.68, p<0.01). All patients with >5,8 dB inter-eye MD difference had RAPD. In Group II, pathological anisocoria (>0.8 mm) was detected using VR pupillometry and 1/8 on standard exam. Qualitative differences in pupillary constriction were observed. In control group anisocoria (0.4-0.8 mm) was detected in 37% (7/19); in all greater in the dark (mean 0.2 mm). Conclusion: In comparison to conventional exam VR pupillometry matched detection rate of RAPD and surpassed detection rate of pathological anisocoria. Longitudinal data on pupillary constriction characteristics could significantly contribute to patient diagnosis and monitoring in clinical studies as well as understanding physiological variability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Natural interaction based visual field prediction in virtual reality - a pilot studymedRxiv · 2026
- A virtual-reality-based asynchronous dichoptic treatment for anisometropic amblyopia: A retrospective pilot clinical trialPhotodiagnosis and Photodynamic Therapy · 2026
- Objective Comparison of Commercially Available Virtual Reality Perimetry Devices: a cross-sectional descriptive study.Research square · 2026
- Virtual Reality-Based Subjective Visual Vertical Testing: A Scoping Review of Measurement Methods.Journal of imaging · 2026
- Automated pupillometric quantification of relative afferent pupillary defect: comparison with neutral density filter grading in unilateral/asymmetric optic neuropathy.Documenta ophthalmologica. Advances in ophthalmology · 2026
- Evaluating the Number of Trials for Stable Virtual Reality-Based Subjective Visual Vertical Measurement in Healthy Adults.Journal of imaging · 2026