Adaptive Post-Processing Recovers Most of the Gap to nnU-Net v2 in Head and Neck GTV Segmentation: A Paired Three-Arm HECKTOR 2025 Benchmark
R. Oyarzun Silva, P. Hernandez Hernandez
Key points
From the paper's conclusion- We separated the two.
Abstract
Background. Accurate delineation of the gross tumour volume (GTV) - primary tumour (GTVp) and nodal disease (GTVn) - on FDG-PET/CT is a critical step of head and neck radiotherapy planning. Comparisons between lightweight custom networks and the auto-configured nnU-Net v2 are usually reported as end-to-end pipelines, conflating the contribution of the network with that of the inference-time post-processing applied on top of it. We separated the two. Methods. MiniUNet3D (custom 3D U-Net, 18.3 M parameters) and nnU-Net v2 (3d_fullres, 88.2 M parameters) were trained on the same 578 FDG-PET/CT cases (85/15 author-defined split of the HECKTOR 2025 Task 1 set, 8 centres) and evaluated on the same internal cohort. Three arms were compared pairwise: MiniUNet3D raw output at a fixed 0.5 threshold, MiniUNet3D with a locked adaptive post-processing pipeline, and nnU-Net v2. Comparisons used paired Wilcoxon tests with bootstrap confidence intervals, Bonferroni and Benjamini-Hochberg correction, and Cohen's d; catastrophic failure (Dice < 0.01) was compared with an exact McNemar test. Cases with an empty reference for a given target were excluded from that target's analysis (n = 98 GTVp, n = 93 GTVn). Results. With post-processing matched off, nnU-Net v2 was superior: median GTVp Dice 0.799 versus 0.592 (mean difference -0.244, 95 % CI -0.300 to -0.191; d = -0.88) and GTVn 0.774 versus 0.598 (d = -0.82). Post-processing raised MiniUNet3D to 0.800 (GTVp) and 0.738 (GTVn), recovering 79 % of that difference. Post-processed, MiniUNet3D matched nnU-Net v2 on GTVp Dice (p = 0.113) but remained inferior on nodal disease after Bonferroni correction (Dice p = 0.041; surface Dice p = 0.049). Catastrophic GTVp failures were 25/98 raw, 8/98 post-processed and 1/98 for nnU-Net v2 (McNemar p = 0.016). Inference took 34 s versus 78 s per case on the same GPU. Conclusions. Post-processing recovered most, but not all, of the difference between the two models, and it did not confer robustness: an eight-fold higher rate of empty contours on small primaries persisted, which is the more consequential difference for planning safety. Pipeline comparisons reported without a post-processing ablation risk attributing to a network what post-processing supplied.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Casting wider than U-Nets: evaluating the role of novel machine learning applications in radiation therapy.BJR artificial intelligence · 2026
- Quantifying multi-lesion detection and localization in whole-body FDG PET/CT with a multimodal foundation model.Physics in medicine and biology · 2026
- Multi-Reference Evaluation of Deep Learning Tumour Segmentation in Multi-Sequence Nasopharyngeal Carcinoma MRI.Diagnostics (Basel, Switzerland) · 2026
- Benchmarking Deep Learning for NSCLC PET/CT Segmentation on a Histologically Confirmed Vietnamese Dataset: Validation and Generalization.Journal of imaging · 2026
- Dose-prediction generalization: Evaluating CNNs on previously unseen patient anatomies and radiation field geometries.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- WaveGate-nnU-Net: Frequency-Domain Inclusion Preserves Segmentation Accuracy under Reduced Training Data in Nasal and Paranasal Sinus CTmedRxiv · 2026