Optimizing Aqueous Humor Liquid Biopsy: Safety and Performance of a Short, Low-Dead-Space Ophthalmic Needle for Anterior Chamber Paracentesis.
Aneal M Singh, Tsai-Chu Yeh, Charles DeBoer, Ahmad Al-Moujahed, Jonathan B Lin, Stephen A Smith, Steven Sanislo, Kholood Janjua,
Key points
From the paper's conclusion- Keywords: Anterior chamber paracentesis; Aqueous humor; Liquid biopsy; Low dead space; Ophthalmic needle
Abstract
PURPOSE: To evaluate the safety, procedural performance, sample recovery, and surgeon preference of an ophthalmic needle designed specifically for anterior chamber (AC) paracentesis. METHODS: In this multicenter study, AC paracentesis was performed in clinic and operating-room settings using a 32-gauge × 4-mm needle with low dead space. The procedure was evaluated using a standardized physician survey. Prespecified outcomes included procedure-related adverse events (primary outcome), needle entry and handling, aspiration and sample recovery, comparative performance versus a 30-gauge needle, and physician preference for future use. RESULTS: A total of 110 needle uses by eight surgeons were included. No ocular complications occurred, including lens or iris injury, hyphema, AC collapse, wound leak, hypotony, infection, or retinal complication, and no procedure required needle exchange or conversion to another device. Two technical events without ocular sequelae were noted, in which needle entry was partial thickness and did not reach the AC (1.8%; exact 95% CI, 0.2%-6.4%). Physicians rated needle entry, handling, and sample recovery as good or excellent. Compared with a 30-gauge needle, the study needle was rated as at least comparable across all assessed domains. All surgeons rated it better or much better for intra-procedural safety and preferred it for future AC taps. CONCLUSIONS AND RELEVANCE: This short, 32-gauge low-dead-space ophthalmic needle demonstrated a favorable safety profile and was preferred over a 30-gauge needle by all surgeons. As aqueous humor liquid biopsy expands in clinical diagnostics and trials, an ophthalmic-specific needle design may help improve the consistency and safety of aqueous humor collection for molecular analysis and broader clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hollow Microneedles in Ophthalmology: From Drug Delivery to Integrated Biosensing.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Exploratory Preclinical Evaluation and Model-Based Pharmacokinetics of a Dual-Drug Biodegradable Intracameral Implant in Rabbits.Pharmaceutics · 2026
- Stepwise 900 µm to 1100 µm Microneedle Selection for Suprachoroidal Triamcinolone Acetonide.Journal of vitreoretinal diseases · 2026
- Improving Patient Comfort During Intravitreal Injections: Anesthesia Strategies in Retina Practice.Journal of patient experience · 2026
- Critical Evaluation of Key Elements in Manufacturing Procedures and Testing Methodologies for Ocular Anti-Infective Thin Film Inserts.Pharmaceuticals (Basel, Switzerland) · 2026
- Needle and Syringe Preference in Cosmetic Botulinum Toxin Treatment of the Upper Face: A Randomized, Controlled, Single-Blind Study.Journal of cosmetic dermatology · 2026