LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes

F. De Lillo, J. Smucler

原始摘要(英文原文)· Original abstract
Electrical stimulation (ES) and transepithelial/transendothelial electrical resistance (TEER) measurements are essential techniques in cell biology and tissue engineering, yet commercial devices for these applications cost between USD 2,500-9,000 and typically offer only one functionality. We present LATEER (Low-cost Arduino-based TEER and Electrical stimulation device), an open-source hardware platform that combines both ES and TEER measurement capabilities at a total cost below USD 100. The device features four independent channels, configurable pulsatile signals (amplitude up to 8.2 V, frequency 0.1-500 Hz, pulse width [&ge;]0.1 ms), and a resistance measurement range of 300 {Omega} to 1 M{Omega}, with <5% error for R [&ge;] 4.7 k{Omega}. LATEER uses commercially available graphite pencil leads as electrodes ({approx}USD 2 vs. USD 350 for commercial Ag/AgCl electrodes), which demonstrated excellent biocompatibility in cell culture. The system includes 3D-printed electrode holders compatible with standard 12-well and 24-well plates, allowing microscope visualization without electrode removal, and a Python-based graphical user interface for parameter configuration and real-time data acquisition. Because the electrodes remain fixed in the plate lid and only a single cable enters the incubator, both stimulation and resistance measurement can run continuously under standard culture conditions (37 {degrees}C, 5% CO2) without removing the plate or repositioning the electrodes, avoiding the temperature excursions and placement variability inherent to manual chopstick measurements. Validation with human pluripotent stem cell-derived cardiomyocytes demonstrated reliable frequency capture (electrical pacing) of the contracting monolayer, with a capture threshold between 250 and 400 mV/mm and controlled pacing across the 0.5-5 Hz range. TEER functionality was verified with mesenchymal stem cells, where the device resolved cell-density-dependent differences in electrical resistance in real time. All design files, firmware, and software are freely available under the CERN-OHL-S v2 license, enabling replication and customization by research laboratories worldwide.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes — 科研速览 Science Skim