Which Attention Helps? A Slide-Level Ablation of Attention-Augmented CNNs for Serous Ovarian Carcinoma Grading
A. Rani, S. Mishra
Key points
From the paper's conclusion- Methods: We present a leakage-controlled, slide-level ablation of attention-augmented CNNs for this binary task on the UBC-OCEAN cohort (259 whole-slide images; 217 HGSC, 42 LGSC).
Abstract
Background: Distinguishing high-grade (HGSC) from low-grade serous carcinoma (LGSC) is clinically consequential yet difficult, as the subtypes share a serous morphology but differ in prognosis and treatment. Prior deep-learning studies report near-perfect accuracy, but often under patch-level evaluation that leaks slide information between training and testing. Methods: We present a leakage-controlled, slide-level ablation of attention-augmented CNNs for this binary task on the UBC-OCEAN cohort (259 whole-slide images; 217 HGSC, 42 LGSC). Under an identical protocol with five-fold slide-grouped cross-validation, Macenko stain normalisation, and slide-level pooling, we compared a from-scratch backbone with no attention, Squeeze-and-Excitation, channel-only CBAM and full CBAM, a lightweight CBAM variant, and an ImageNet-pretrained MobileNet with a differential-attention module. A pathology foundation model (Phikon) with attention-based multiple-instance aggregation was evaluated as a modern benchmark. Results are reported across three training seeds, with decision thresholds selected within folds, and compared using DeLong and McNemar tests with Holm correction and bootstrap confidence intervals. Results: The pretrained model performed best (AUC 0.862 {+/-} 0.005, MCC 0.460) and was the most stable across seeds. It significantly outranked both the Squeeze-and-Excitation model (DeLong, Holm p = 0.002) and the no-attention baseline (p = 0.019). Full CBAM also outranked Squeeze-and-Excitation (p = 0.010), but adding the spatial-attention branch to channel attention produced no detectable change (0.824 to 0.822; p = 0.50), and the lightweight model did not match the deep one once training variance was accounted for. The foundation-model benchmark reached AUC 0.834 {+/-}0.018, below the pretrained MobileNet. A colour-only classifier reached AUC 0.66, indicating part of the separability is attributable to stain and colour rather than morphology. Conclusion: Under leakage-free evaluation, performance is more modest than commonly reported. Transfer learning and the avoidance of a weak channel-only configuration produced the clearest gains, while finer attention design, network size and a pathology-specific foundation model produced no detectable improvement. With only 42 LGSC slides the task remains underpowered for finer distinctions, and most architectural differences could not be resolved.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Structure-aware generalization for heterogeneous histopathology via prototype-based multiple instance learningnpj Digital Medicine · 2026
- Weakly-Supervised Gated Attention Multiple Instance Learning for Multi-Center Cervical Cytology Slide TriagemedRxiv · 2026
- SlideJev: Order-Stable and Tissue-Grounded Jev Decisions for Whole-Slide PathologyarXiv · 2026
- RACR-MIL: Rank-aware contextual reasoning for weakly supervised grading of squamous cell carcinoma using whole slide images.Medical image analysis · 2026
- Where slide-level foundation-model classifiers fail on atypical breast lesionsarXiv · 2026
- SemaNorm: Stain Normalization via Semantic and Morphology Alignment for Robust Cross-Hospital Computational PathologyarXiv · 2026