Low-intensity focused ultrasound versus conventional corticosteroid therapy for idiopathic granulomatous mastitis: improved pain relief, quality of life, and favorable safety profile.
Haixing Wang, Hongyan Wang, Kai Li, Ge Zhang, Wenjie Ning
Department of HIFU Treatment Room, The Fourth Hospital of Shijiazhuang Shijiazhuang 050000, Hebei, China. · Department of Obstetrics, Shijiazhuang People's Hospital Shijiazhuang 050000, Hebei, China.
Key points
From the paper's conclusion- Low-intensity focused ultrasound monotherapy is associated with superior pain relief, greater improvement in quality of life, higher clinical response rates, and a more favorable safety profile than corticosteroid injections in patients with IGM.
Abstract
PURPOSE: Idiopathic Granulomatous mastitis (IGM) is a chronic inflammatory breast disease for which conventional corticosteroid therapy is limited by substantial adverse effects. This study aimed to compare the analgesic efficacy, quality-of-life improvement, and safety of low-intensity focused ultrasound (LIFU) monotherapy versus intralesional corticosteroid injections in patients with IGM. METHODS: This retrospective study included individuals diagnosed with IGM between September 2021 and December 2025. Patients received either intralesional corticosteroid injections (hormone group, n = 124) or low-intensity focused ultrasound monotherapy (LIFU group, n = 117). Primary outcomes were pain intensity on the 10-cm Visual Analog Scale (VAS) and health-related quality of life using the 36-Item Short Form Health Survey (SF-36). Secondary outcomes included overall clinical response, inflammatory markers, ultrasound lesion characteristics and volume reduction rate, adverse events, and recurrence. RESULTS: At week 12, the LIFU group had significantly lower VAS pain scores (2.86 ± 0.74 vs. 3.52 ± 0.86, P < 0.001). Improvements were also observed across other SF-36 domains, with six of eight domains remaining significant after correction for multiple comparisons. The overall response rate (ORR) in LIFU group was 94.02%, which was significantly higher than the 83.87% observed in the corticosteroid group (P = 0.013). Inflammatory markers were markedly lower with LIFU (CRP: 7.12 ± 2.37 vs. 8.96 ± 2.98 mg/L, P < 0.001; ESR: 16.92 ± 5.61 vs. 19.34 ± 6.44 mm/h, P = 0.002), and lesion volume reduction was greater (60.12 ± 11.95% vs. 55.26 ± 12.48%, P = 0.002). Adverse event rates (10.26% vs. 25.00%, P = 0.003) and recurrence rates (7.89% vs. 29.03%, P = 0.001) were both significantly lower in the LIFU group. CONCLUSION: Low-intensity focused ultrasound monotherapy is associated with superior pain relief, greater improvement in quality of life, higher clinical response rates, and a more favorable safety profile than corticosteroid injections in patients with IGM.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative efficacy and safety of intralesional corticosteroids vs. systemic therapy and surgery for idiopathic granulomatous mastitis: a systematic review and network meta-analysisFrontiers in Medicine · 2026
- Predictors of Response to Corticosteroid Therapy in Idiopathic Granulomatous Mastitis: A Retrospective Cohort Study of 176 Patients.Medicina (Kaunas, Lithuania) · 2026
- Microwave Ablation for Granulomatous Lobular Mastitis: A Narrative Review.Medical science monitor : international medical journal of experimental and clinical research · 2026
- Lesion Diameter Versus Inflammatory Biomarkers and Clinical Severity in Predicting Treatment Selection in Idiopathic Granulomatous Mastitis.World journal of surgery · 2026
- Idiopathic granulomatous mastitis in the United Arab Emirates: a retrospective case series of clinical features, management, and outcomes.Clinical rheumatology · 2026
- Idiopathic granulomatous mastitis a mimicking disease: a case report.AME case reports · 2026