Feasibility, tolerability, and safety of cyanoacrylate glue for silicone stent fixation in external dacryocystorhinostomy.
Marlos Rodrigues Lopes E Silva, Michael Knafo, Mostafa Bondok, Diogo Batista de Queiroz Silveira, Anne-Xuan Lan Nguyen, Patricia Mitiko Santello Akaishi, Leonardo Lando
Oculoplastic Surgery Service, Department of Ophthalmology, Universidade Federal de Goiás, Goiânia, GO, Brazil. · Faculté de Médecine, Université de Montréal, Montréal, Québec, Canada.
Key points
From the paper's conclusion- Cyanoacrylate fixation was associated with favorable patient tolerability and no increase in complication rates compared with conventional knotted fixation. These findings suggest that cyanoacrylate glue may be a safe and well-tolerated alternative for silicone stent fixation during external dacryocystorhinostomy.
Abstract
PURPOSE: To compare surgical outcomes and patient tolerability between conventional knotted fixation and a novel technique using cyanoacrylate gel glue to secure the silicone stent during external dacryocystorhinostomy. METHODS: This retrospective study included 70 patients who underwent external dacryocystorhinostomy, of whom 40 received cyanoacrylate glue fixation (study group) and 30 underwent conventional knotted fixation (control group). Patients with congenital or acquired lacrimal obstruction and a minimum follow-up period of 6 months were included. All procedures were performed by the same surgeon at a single institution. Patient tolerability, including foreign body sensation, sneezing, and nasal secretion, and surgical complications, including glue-induced toxicity, infection, stent extrusion, mobilization, release, and pyogenic granuloma, were assessed. Data were analyzed using descriptive statistics and nonparametric tests. RESULTS: The median patient age was 69.0 years (range, 3-90 years), and most patients were women (81.4%, n=57). There were no significant differences between the groups in age (p=0.264) or sex (p=0.213). Symptoms were reported by 34.3% of patients and were significantly more frequent in the control group than in the study group (33.3% vs. 10.0%, p<0.001). Foreign body sensation (p=0.002), sneezing (p=0.012), and nasal secretion (p<0.001) were all significantly more common in the control group. Overall, complications were infrequent, with no significant between-group differences in stent release (17.5% vs. 20.0%, p=0.790), mobilization (5.0% vs. 16.7%, p=0.130), or infection (2.9% vs. 0%, p=0.503). No cases of glue-induced toxicity were observed. Follow-up duration did not differ significantly between the groups. CONCLUSIONS: Cyanoacrylate fixation was associated with favorable patient tolerability and no increase in complication rates compared with conventional knotted fixation. These findings suggest that cyanoacrylate glue may be a safe and well-tolerated alternative for silicone stent fixation during external dacryocystorhinostomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Long-term efficacy and safety of steroid-eluting sinonasal stents in endoscopic dacryocystorhinostomy: a prospective, single-arm study.Frontiers in surgery · 2026
- Endoscopic dacryocystorhinostomy with versus without silicone intubation in chronic dacryocystitis: a comparative meta-analysis.International ophthalmology · 2026
- Clinical Profile and Surgical Outcomes of External Dacryocystorhinostomy in a Public Tertiary Training Hospital in the Philippines.Acta medica Philippina · 2026
- Extraocularly Manipulated Flangeless Intrascleral Haptic Fixation of Intraocular Lens Using Zigzag Needles.Cureus · 2026
- Outcomes of 3-mm lacrimal balloon dilation in post-DCR common canalicular mucosal stenosis: A minimally invasive recovery approach.Journal francais d'ophtalmologie · 2026
- Early clinical outcomes of the trans-ocular threading technique for four-point flanged scleral fixation of intraocular lenses: a case series.BMC ophthalmology · 2026