Hybrid 99mTc-DTPA Dynamic Scintigraphy and SPECT/CT Overturn Presumed Renal Agenesis by Characterizing a Functioning Pelvic Ectopic Kidney in Pediatric VACTERL Association: An Observational Analytic Study
Fransiska Nina Josi, Kharisma Perdani Kusumahstuti, Hendra Budiawan, Trias Nugrahadi
Dr. Hasan Sadikin General Hospital
Key points
From the paper's conclusion- Conclusion: Hybrid 99mTc-DTPA scintigraphy and SPECT/CT distinguished a functioning pelvic ectopic kidney from presumed renal agenesis, quantified 34.6% viable renal function and reduced the risk of intraoperative vascular injury during spinal deformity correction.
Abstract
Background: Renal anomalies occur in over 60% of children with VACTERL association, and ultrasonography often misses pelvic ectopia, leading to false diagnoses of renal agenesis. Distinguishing agenesis from functional ectopia is important before major spinal surgery. Objective: To characterize differential renal function and anatomical location in a child with suspected VACTERL association and sonographically presumed renal agenesis, using hybrid 99mTc-DTPA dynamic scintigraphy and SPECT/CT. Methods: A 4-year-old girl with thoracic hemivertebra, secundum atrial septal defect, thoracolumbar scoliosis (Cobb angle 32°) and a non-visualized left kidney on screening ultrasound underwent dynamic planar 99mTc-DTPA scintigraphy (74 MBq) followed by low-dose hybrid SPECT/CT at Dr. Hasan Sadikin General Hospital, Bandung, Indonesia. Differential renal function (DRF), Gates glomerular filtration rate (GFR) and renographic drainage kinetics were evaluated. Results: Planar scintigraphy overturned the diagnosis of renal agenesis by showing functioning tissue in both kidneys (DRF 34.6% left vs 65.4% right; net counts 5,873 vs 11,092 cpm). Gates GFR was 21.2 mL/min for the left and 40.0 mL/min for the right kidney (global 61.2 mL/min; 209.8 mL/min/1.73 m² normalized to body surface area). The left renogram showed delayed transit (Tmax 17.0 vs 11.0 min; retention index 0.897 vs 0.577). SPECT/CT localized the functioning left kidney to the pre-sacral pelvis, anterior to S1–S3, supporting a posterior-only approach to spinal instrumentation. Conclusion: Hybrid 99mTc-DTPA scintigraphy and SPECT/CT distinguished a functioning pelvic ectopic kidney from presumed renal agenesis, quantified 34.6% viable renal function and reduced the risk of intraoperative vascular injury during spinal deformity correction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantifying Severe Functional Asymmetry and Superior Pole Cortical Loss in Pediatric Hydronephrosis: A 99mTc-DMSA Scintigraphy and Hybrid SPECT/CT Observational Analytic StudySriwijaya Journal of Radiology and Imaging Research · 2026
- Incidentally detected crossed nonfused renal ectopia on contrast-enhanced trauma CT: A case report and review of the literatureRadiology Case Reports · 2026
- Recognizing a duplicated inferior vena cava during radical nephrectomy for papillary renal cell carcinoma: A case report.Urology case reports · 2026
- Rare anatomical variant of a duplicate renal vein traversing through the L1 vertebral body in a U.S. Veteran presenting with spine pain: an imaging case review.The Journal of the Canadian Chiropractic Association · 2026
- Persistent Colonic Activity on 99mTc-MDP Whole Bone Scintigraphy Revealing a Complex Ureterorectal Fistula.Clinical nuclear medicine · 2026
- Paediatric nephro-urology imaging: updates in renal scintigraphy and pitfalls.Seminars in nuclear medicine · 2026