Key points

From the paper's conclusion
  • Conclusion: Hybrid 99mTc-DTPA scintigraphy and SPECT/CT distinguished a functioning pelvic ectopic kidney from presumed renal agenesis, quantified 34.6% viable renal function and reduced the risk of intraoperative vascular injury during spinal deformity correction.

Abstract

Background: Renal anomalies occur in over 60% of children with VACTERL association, and ultrasonography often misses pelvic ectopia, leading to false diagnoses of renal agenesis. Distinguishing agenesis from functional ectopia is important before major spinal surgery. Objective: To characterize differential renal function and anatomical location in a child with suspected VACTERL association and sonographically presumed renal agenesis, using hybrid 99mTc-DTPA dynamic scintigraphy and SPECT/CT. Methods: A 4-year-old girl with thoracic hemivertebra, secundum atrial septal defect, thoracolumbar scoliosis (Cobb angle 32°) and a non-visualized left kidney on screening ultrasound underwent dynamic planar 99mTc-DTPA scintigraphy (74 MBq) followed by low-dose hybrid SPECT/CT at Dr. Hasan Sadikin General Hospital, Bandung, Indonesia. Differential renal function (DRF), Gates glomerular filtration rate (GFR) and renographic drainage kinetics were evaluated. Results: Planar scintigraphy overturned the diagnosis of renal agenesis by showing functioning tissue in both kidneys (DRF 34.6% left vs 65.4% right; net counts 5,873 vs 11,092 cpm). Gates GFR was 21.2 mL/min for the left and 40.0 mL/min for the right kidney (global 61.2 mL/min; 209.8 mL/min/1.73 m² normalized to body surface area). The left renogram showed delayed transit (Tmax 17.0 vs 11.0 min; retention index 0.897 vs 0.577). SPECT/CT localized the functioning left kidney to the pre-sacral pelvis, anterior to S1–S3, supporting a posterior-only approach to spinal instrumentation. Conclusion: Hybrid 99mTc-DTPA scintigraphy and SPECT/CT distinguished a functioning pelvic ectopic kidney from presumed renal agenesis, quantified 34.6% viable renal function and reduced the risk of intraoperative vascular injury during spinal deformity correction.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers