International Journal of EngineeringOpen accessHeat sink

CFD Investigation of Thermal and Electrical Behavior of Photovoltaic Modules Equipped with Heat Sinks and Vortex Generators

A. J. Al-Maliki, Davood Domiri Ganji, Mofid Gorji-Bandpy

University of Wasit · Babol Noshirvani University of Technology

Computational

Key points

From the paper's conclusion
  • The results demonstrate that the reduction of duct height from 200 mm to 100 mm can decrease the PV surface temperature by 10 °C and among all finned cases, the array with 22 fins exhibited maximum cooling whilst the best compromise between heat-transfer enhancement and pressure drop was provided by using an arrangement with 18 fins in a given area.

Abstract

The Photovoltaic (PV) modules suffer performance losses at high operating temperatures, especially in hot and low-wind conditions, making effective cooling essential. This study numerically investigates a fan-assisted PV cooling duct equipped with heat sinks and vortex generators (VGs) using computational fluid dynamics (CFD). The novelty of the work lies in the integrated evaluation of duct height, fin spacing, VG height, inclination angle, and attack angle within a single forced-convection framework. The model was validated against published benchmark data with deviations below 5%. The results demonstrate that the reduction of duct height from 200 mm to 100 mm can decrease the PV surface temperature by 10 °C and among all finned cases, the array with 22 fins exhibited maximum cooling whilst the best compromise between heat-transfer enhancement and pressure drop was provided by using an arrangement with 18 fins in a given area. Thermal performance improved with increasing VG height, but the 40 mm VG gave the greatest heat-transfer coefficient at the cost of relatively high-pressure loss. In the 90° case, VG orientation achieved the highest electrical efficiency at (Re = 11000), achieving an electrical efficiency of 16.9% and maximum achievable electrical power output of approximately 44.21 W, after accounting for DC fan power consumption, with the 90° VG configuration still showing the highest system electrical power. The 30° scenario, by contrast, resulted in the best thermal efficiency–nearly 80% and the greatest thermal power–over 420 W demonstrating practical merit in providing guidance for selecting PV cooling configurations based on specific electrical-output or thermal-recovery priorities.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

CFD Investigation of Thermal and Electrical Behavior of Photovoltaic Modules Equipped with Heat Sinks and Vortex Generators — Science Skim