The Catheter-Based Mechanical Dilation Using a Spindle-Shaped Delivery Assist Catheter for Difficult-to-Access Cerebral Vasospasm Following Subarachnoid Hemorrhage.
Takeshi Okada, Naoki Toma, Nami Wada, Hideki Kanamaru, Fumihiro Kawakita, Ryuta Yasuda, Hidenori Suzuki
Department of Neurosurgery, Mie University Graduate School of Medicine, Tsu, Mie, Japan.
Key points
From the paper's conclusion- Catheter-based mechanical dilation using a spindle-shaped delivery assist catheter may be considered as a feasible option for treating CVS when conventional balloon angioplasty is technically difficult. Further experience is required to determine its safety, efficacy, and durability.
Abstract
OBJECTIVE: Cerebral vasospasm (CVS) following subarachnoid hemorrhage (SAH) is sometimes difficult to treat with conventional balloon angioplasty due to limited device accessibility. We report catheter-based mechanical dilation using a spindle-shaped delivery assist catheter for CVS that is difficult to access with conventional balloon catheters. CASE PRESENTATION: A 70-year-old man presented with severe SAH due to a ruptured anterior communicating artery aneurysm and underwent coil embolization along with ventricular drainage. On day 7, CVS of the left M1 segment of the middle cerebral artery (MCA) was treated with balloon angioplasty. On day 9, severe CVS of the left A1 segment of the anterior cerebral artery and the left M2 segment of the MCA was identified. A spindle-shaped delivery assist catheter was advanced to the distal left A1 segment, and mechanical dilation was performed by passing its bulb segment through the stenotic lesion. Subsequent angiography demonstrated vessel dilation. For the CVS in the left M2 segment, balloon angioplasty and selective intra-arterial fasudil hydrochloride infusion were performed. On day 14, newly developed vasospasm in the distal left M2 segment, beyond the segment previously treated with balloon angioplasty, was successfully dilated using the same technique. No procedure-related complications were observed, and no cerebral infarction developed in the treated vascular territories. CONCLUSION: Catheter-based mechanical dilation using a spindle-shaped delivery assist catheter may be considered as a feasible option for treating CVS when conventional balloon angioplasty is technically difficult. Further experience is required to determine its safety, efficacy, and durability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Repurposing a Dual-Head Programmable Power Injector for Controlled Intra-Arterial Vasodilator Delivery During Cerebral Vasospasm Treatment.World neurosurgery · 2026
- Extensive Cerebral Infarction Following Cerebral Vasospasm Despite Repeated Endovascular Treatment in a Patient With Twig-Like Middle Cerebral Artery.The Neurohospitalist · 2026
- Balloon Passage via Microwire Navigation Technology for Severe Stenosis of Middle Cerebral Artery: A Case Report.Clinical case reports · 2026
- A steerable microcatheter-stabilizer strategy for stent-assisted coiling of a wide-neck middle cerebral artery aneurysm with an acutely angulated incorporated branch.Surgical neurology international · 2026
- Rescue clazosentan for symptomatic cerebral vasospasm following subarachnoid hemorrhage due to anterior cranial fossa dural arteriovenous fistula: A case report with serial angiographic evaluationSurgical Neurology International · 2026
- Direct V2 vertebral artery puncture as rescue access for basilar thrombectomy: a technical note.Neuroradiology · 2026