Mucoadhesive Drug Delivery Systems: A Critical Appraisal of Adhesion Mechanisms, Formulation Strategies and Translational Prospects
Amit Semwal, Mayank Agrahari, Vineet Joshi, Ridhi Koul, Rohit Kumar Trivedi
Doon University
Key points
From the paper's conclusion- Research priorities are proposed for benchmark materials, standardised reporting, mechanistically informative characterisation and trial designs capable of isolating the contribution of adhesion from concurrent drug, excipient and vehicle effects.
Abstract
Mucoadhesive drug delivery systems have been developed for more than four decades on the premise that prolonging contact between a dosage form and a mucosal surface increases local drug concentration, extends residence time and improves absorption. The premise is intuitively attractive and is supported by a large materials-science literature, yet the clinical output of the field remains modest relative to the volume of preclinical publication. This critical narrative review examines why that discrepancy persists and what would be required to resolve it. Literature retrieved from Europe PMC, Crossref Metadata Search and the Directory of Open Access Journals, supplemented by backward and forward citation tracking, was appraised for methodological adequacy, internal consistency and translational relevance rather than catalogued by dosage form. Four principal conclusions emerge. The classical mechanistic theories of mucoadhesion retain descriptive value but generate few falsifiable predictions, and the shift towards covalent and dynamic-covalent interfacial chemistry has outpaced the conceptual framework used to interpret it. The adhesion substrate is poorly controlled: commercially purified mucins differ from native mucus and from one another in ways that materially alter measured polymer interaction, so a substantial proportion of comparative data reflects substrate selection as much as material performance. The long-standing opposition between mucoadhesive and mucus-penetrating design is better understood as a site-specific optimisation problem governed by mucus turnover than as a general contest between rival philosophies, and available in vivo evidence does not establish the superiority of either strategy across mucosal sites. Measurement remains the central methodological weakness, because detachment force, rheological synergism, particle tracking and interfacial techniques probe different physical phenomena, are seldom reported with parameters sufficient for cross-study comparison, and lack agreed reference materials. The clinical evidence base is correspondingly thin and dominated by small trials of heterogeneous formulations. Research priorities are proposed for benchmark materials, standardised reporting, mechanistically informative characterisation and trial designs capable of isolating the contribution of adhesion from concurrent drug, excipient and vehicle effects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advances in mucoadhesive drug delivery systems: Mechanistic insights, pharmacological performance, and translational pathways.Current research in pharmacology and drug discovery · 2026
- From Mucin to Smart Medicine: Engineering Mucin-Based Biomaterials for Advanced and Responsive Drug Delivery.Advances in pharmacological and pharmaceutical sciences · 2026
- Advances in mucoadhesive and mucus-penetrating materials, nano-formulations, and in situ gelling systems for nasal drug deliveryExpert Opinion on Drug Delivery · 2026
- Designing adhesive hydrogels for oral diseases treatment.Materials today. Bio · 2026
- Effect of mucosal hydration on time-dependent mucoadhesion of polymeric nanocomposite microspheres to ovine nasal mucosa: relationship to swelling kinetics.Frontiers in pharmacology · 2026
- Overcoming Oral Mucosal Barriers: Next-Generation Oromucosal Formulation Strategies for Efficient Therapy of Oral Diseases.Journal of functional biomaterials · 2026