Imaging science in dentistry

Reliability of the QUADAS-2 checklist in AI-based medical imaging: A comparison of human reviewers and ChatGPT-4o.

Mahmood Dashti, Farshad Khosraviani, Niloofar Ghadimi, Saman Kalantari, Mohammad Hosein Amirzade-Iranaq, Ghazal Hemmati, Sarah Arzani, Zeynab Pirayesh,

Dentofacial Deformities Research Center, Research Institute of Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran. · Department of Restorative Dentistry, UCLA School of Dentistry, Los Angeles, CA, USA.

Key points

From the paper's conclusion
  • These findings suggest that QUADAS-2 may have limited reproducibility when applied to AI-based imaging research under the present study conditions, although the observed inconsistency may also reflect features of the study design and assessment setting. These findings support consideration of AI-specific tools such as QUADAS-AI for future bias assessment in AI-driven medical imaging.

Abstract

PURPOSE: Artificial intelligence is reshaping medical imaging, yet reliable bias assessment in this context remains insufficiently studied. It remains unclear whether the widely used QUADAS-2 checklist provides reproducible evaluations in AI-based imaging studies. Therefore, we compared human and ChatGPT-4o assessments to examine the reproducibility of QUADAS-2 in this setting. MATERIALS AND METHODS: Twenty PubMed-indexed AI-based dental imaging studies were analyzed by five human reviewers and five independent ChatGPT-4o runs using identical categorical outputs. Reliability within and between groups was quantified using Fleiss' kappa. RESULTS: Human agreement ranged from -0.07 to 0.22, with only the reference standard domain reaching fair reliability (κ=0.22, P<0.001). ChatGPT-4o produced kappa values from -0.17 to 0.56, with the highest consistency observed in the index test domain (κ=0.56, P<0.001). Between-group kappa values remained near zero across domains, except in items uniformly classified as low risk. These patterns suggest that QUADAS-2 may yield inconsistent judgments across both groups, despite evaluation of 20 studies and repeated AI classifications. CONCLUSION: These findings suggest that QUADAS-2 may have limited reproducibility when applied to AI-based imaging research under the present study conditions, although the observed inconsistency may also reflect features of the study design and assessment setting. These findings support consideration of AI-specific tools such as QUADAS-AI for future bias assessment in AI-driven medical imaging.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers