Integrated optimization of electroplating wastewater treatment: A comparative assessment of physicochemical treatment configurations and process enhancement using response surface methodology.

Soumaya Ibrahimi, Aicha Gasmi, Karim Kriaa, Farid Fadhillah, Majeed Ali Habeeb, Djamel Ghernaout, Noureddine Elboughdiri, Ahmed Hannachi

原始摘要(英文原文)· Original abstract
This study assesses physicochemical treatment methods for industrial electroplating wastewater (EPW). Monitoring at a full-scale Tunisian facility revealed considerable instability in conventional systems. Residual nickel concentrations ranged from 0.02 ± 0.01 to 60 ± 0.4 mg/L. Chloride levels consistently exceeded regulatory thresholds, ranging from 442 ± 9-1418 ± 10 mg/L. Over 24 weeks, three treatment configurations were evaluated: ferric chloride-based coagulation (Configuration 1), polyaluminum chloride coagulation (Configuration 2), and lime slurry-based chemical attack (Configuration 3). Configuration 3 showed the most consistent performance. It achieved 99% chromium removal, 97% nickel removal, and 50% chloride reduction, while reducing chemical operating costs by 69% (0. 134 €· m ³ compared to 0. 432 €·m-3). A novel optimization strategy is presented that explicitly incorporates variability in influent nickel concentration ([Ni]ᵢ, 33-92 mg/L) as an independent factor. This is applied within a Response Surface Methodology-Central Composite Design, alongside pH (6.3-9.7) and flocculant dosage (2.2-9.4 mg/L). Fluctuations in wastewater composition are treated as a controlled design variable rather than experimental noise. This approach produces a robust predictive model ([Ni]f = f([Ni]ᵢ, pH, [A-PAM]) with high accuracy (R² = 0.9917). The resulting equation enables real- time adaptive chemical dosing. Operators can calculate optimal pH and flocculant requirements based on measured influent concentrations. Statistical analysis identified significant pH-metal loading interactions (F = 5.70, p = 0.044). This confirms that optimal parameters systematically shift with influent composition. Under model-predicted conditions, residual nickel consistently remained below 2 mg/L, despite substantial influent variability. This ensures regulatory compliance. The integrated approach shows that variability- responsive optimization enhances treatment efficacy, operational stability, and economic efficiency.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Integrated optimization of electroplating wastewater treatment: A comparative assessment of physicochemical treatment configurations and process enhancement using response surface methodology. — 科研速览 Science Skim