科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia2026-08-18

Effects of early shoulder exercise on functional recovery after cardiac implantable electronic device implantation: A 3-year randomized cohort follow-up.

Muharrem Said Cosgun, Cansu Cosgun

一句话结论 · In one sentence

Early postoperative shoulder exercise after CIED implantation provides sustained improvements in shoulder function and physical QoL without compromising lead safety.

原始摘要(英文原文)· Original abstract
BACKGROUND: Shoulder dysfunction after cardiac implantable electronic device (CIED) implantation may impair upper-extremity function and quality of life (QoL). Although a prior randomized trial demonstrated short-term benefits of early postoperative exercises, long-term outcomes remain unclear. AIM: To evaluate the 3-year efficacy and safety of an early postoperative shoulder exercise protocol after CIED implantation. METHODS: Of 92 patients randomized in the original trial, 82 completed the 3-year follow-up. Participants had completed a 6-week intervention consisting of pendulum exercises (PE), stretching & strengthening exercises (SSE) or standard care, without further structured exercise. Outcomes included Visual Analog Scale (VAS) pain scores, grip strength, shoulder flexion and abduction range of motion (ROM), Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH), and the Physical and Mental Component Summary scores (PCS and MCS) of the 36-Item Short-Form Survey (SF-36). Lead-related complications were also assessed. RESULTS: VAS and SF-36 MCS scores were comparable across groups. However, compared with standard care, both exercise groups maintained superior outcomes at 3 years for grip strength (PE: +9.0 kgf; SSE: +9.0 kgf), shoulder flexion ROM (PE: +10.0°; SSE: +11.0°), shoulder abduction ROM (PE: +7.0°; SSE: +7.0°), QuickDASH (PE: -5.0 points; SSE: -6.0 points), and SF-36 PCS (PE: +9.0 points; SSE: +10.0 points) (all P < 0.05). No lead-related complications occurred during follow-up. CONCLUSION: Early postoperative shoulder exercise after CIED implantation provides sustained improvements in shoulder function and physical QoL without compromising lead safety. CLINICALTRIALS: gov, NCT07496554. https://clinicaltrials.gov/study/NCT07496554.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Effects of early shoulder exercise on functional recovery after cardiac implantable electronic device implantation: A 3-year randomized cohort follow-up. — 科研速览 Science Skim