From the paper's conclusion
  • We propose PhyCL-Net, a time-domain network without an explicit spectral feature branch.

Abstract

Fall detection on wearable edge devices requires high sensitivity within tight latency, memory and energy budgets. We propose PhyCL-Net, a time-domain network without an explicit spectral feature branch. It combines a physics-guided dynamic kernel (PDK), which adapts temporal receptive fields to local signal dynamics, with jerk-aware fall-aware attention (FAA), which emphasises transient segments. A hierarchical dual-view contrastive regulariser is used only during training, and its auxiliary heads are removed for deployment. On SisFall with 12-fold leave-one-subject-out (LOSO) validation, PhyCL-Net achieves 98.21 ± 0.10% accuracy and 98.16 ± 0.10% Macro-F1 across five seeds, with 1.049M parameters and 0.15 GFLOPs. Compared with a matched spectral baseline, its median single-thread CPU latency is 31.6% lower (125.99 ms). On the empirical ROC curve, the false-positive rate (FPR) at a 95% true-positive rate (TPR) is 0.72%, but the TPR at 1% FPR is 2.73 percentage points lower than that of the spectral baseline.