Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews

Lower Extremity Assessment Scale: A Simple Patient-Reported Tool Validated Against Patient-Reported Outcomes Measurement Information System Physical Function.

Tyler Forbes, Joseph Cavataio, Alyxandra Camello, Anagha Purushotham, Andrew Robinson, Kevin Blue, Rahul Vaidya

From the Department of Orthopedic Surgery, Wayne State University, Detroit, MI.

Key points

From the paper's conclusion
  • The LEA is a valid, efficient, and patient-friendly outcome measure for postoperative lower extremity trauma. It correlates strongly with PROMIS-PF while providing insight into limb-specific function, supporting its integration into clinical practice and research.

Abstract

INTRODUCTION: Accurate assessment of recovery after lower extremity trauma is critical in orthopaedics. The Patient-Reported Outcomes Measurement Information System Physical Function (PROMIS-PF) scale is widely used but may introduce ambiguity for lower limb-related impairments. To address this limitation, the Lower Extremity Assessment (LEA) scale was developed. It is a brief patient-reported tool focused on assessing pain, mobility, and gait. The aim of this study was to validate LEA by comparing it with PROMIS in postoperative trauma patients. METHODS: An IRB-approved prospective cross-sectional study of 232 patients was conducted among patients who had undergone surgery for lower extremity fractures, joint pathology, or soft-tissue injuries at a level I US trauma center. Participants completed the eight-item PROMIS Physical Function form (T-scores) and the three-question LEA survey (0-7 scale). Correlations were analyzed using Spearman ρ and Pearson r, with subgroup analyses by injury type and postoperative intervals. RESULTS: PROMIS-PF T-scores ranged from 22.7 to 56.9 (median 40.2), while LEA scores ranged from 0 to 7 (median 4). LEA demonstrated a strong correlation with PROMIS (Spearman ρ = 0.701; P < 0.001; Pearson r = 0.68; P < 0.001). Correlations were not different across recovery phases (<3 months vs. > 6 months; P = 0.93). CONCLUSION: The LEA is a valid, efficient, and patient-friendly outcome measure for postoperative lower extremity trauma. It correlates strongly with PROMIS-PF while providing insight into limb-specific function, supporting its integration into clinical practice and research.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers