Journal of Bone and Joint Infection
Bone-preserving one-stage all-part exchange within the cementless osseointegration window for acute postoperative periprosthetic joint infection after total knee arthroplasty: a case report with 5-year follow-up
Chayut Chaiperm, Derek F. Amanatullah
Case report
Key points
From the paper's conclusion- Infection control (MSIS Tier 1) was maintained at 5-year follow-up.
Abstract
A 75-year-old man developed acute periprosthetic infection 1 month after cementless total knee arthroplasty, with sinus tracts precluding debridement, antibiotics, and implant retention. Because osseointegration was incomplete, all components were removed with minimal bone loss and single-stage reimplantation performed with antibiotic-loaded cement. Infection control (MSIS Tier 1) was maintained at 5-year follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Management of Periprosthetic Total Knee Infection with Partial Hardware Removal: A Case Report.Journal of orthopaedic case reports · 2026
- Toward Evidence-Informed Staging in Septic Revision Total Knee Arthroplasty: One-Stage, 1.5-Stage, or Two-Stage?Cureus · 2026
- The 1.5-Stage Exchange for the Management of Periprosthetic Joint Infection Following Total Knee Arthroplasty: Clarification of Terminology, Review of Clinical Outcomes, and Surgical Technique.The Journal of bone and joint surgery. American volume · 2026
- Sobering Outcomes after Two-Stage Revision for Periprosthetic Joint Infection Among Patients Who Have Revision Total Knee Arthroplasty Components.The Journal of arthroplasty · 2026
- One-Year Infection Eradication and Clinical Outcomes After Completed Two-Stage Revision for Hip and Knee Periprosthetic Joint Infection: A Retrospective Cohort Study.Cureus · 2026
- Limb Salvage After Failed Infected Total Knee Arthroplasty: A Comparison of Cement-Based Artificial Arthrodesis and External Fixator Arthrodesis.Life (Basel, Switzerland) · 2026