Process-based evaluation of green roof models for assessment of heat mitigation efficacy in WRF (v4.3.1) and EnergyPlus (v8.6.0)
Maria Martinez Mendoza, Alireza Saeedi, James Voogt, E. Scott Krayenhoff
Western University · University of Guelph
Key points
From the paper's conclusion- This study addresses that gap by evaluating two configurations of EcoRoof, the green roof module from EnergyPlus (ER o for the original version of the model, and ER m for a modified version), and a multilayer green roof parametrization for WRF (WRF-MLGR) (Heusinger et al., 2018; Sailor, 2008; Zonato et al., 2021).
Abstract
Abstract. Green roofs mitigate urban heat, but to fully assess their impact, green roof models must be integrated into urban climate models, where they provide critical surface boundary conditions. Ensuring their reliability requires evaluation, yet such efforts remain limited in the literature. This study addresses that gap by evaluating two configurations of EcoRoof, the green roof module from EnergyPlus (ERo for the original version of the model, and ERm for a modified version), and a multilayer green roof parametrization for WRF (WRF-MLGR) (Heusinger et al., 2018; Sailor, 2008; Zonato et al., 2021). These models were tested against field observations from a monitored green roof in London, Ontario, focusing on latent heat flux (Qe), surface temperature (Tsurf), storage heat flux (Qg) and soil water content (SWC). Model performance varied by variable. The two EcoRoof versions showed similar performance, with mean RMSE across study periods of approximately 56–60 W m-2 for Qe, 3–4 °C for Tsurf, 22 W m-2 for Qg, and 0.03 m3 m-3 for SWC. Performance for Qe was comparable across models; however, WRF-MLGR exhibited much larger errors for Qg (with mean RMSE exceeding 100 W m-2) and SWC (0.06 m3 m-3), along with higher Tsurf deviations (~5 °C). Overall, EcoRoof provided a more consistent representation of the daytime energy balance, whereas WRF-MLGR showed structural biases in surface heating. These findings highlight the importance of process-level evaluation for urban climate applications and underscore the need for continued model development to address the structural limitations in green roof parametrizations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Process-based upgrades to the WRF multi-layer green-roof scheme (WRF-MLGR v2.0) and evaluation against field observationsGeoscientific Model Development · 2026
- WRF assessment of local climate zone dependent cooling effects of cool and green roofs during a Riyadh heatwaveFrontiers in Environmental Science · 2026
- Research on the coupling mechanism between green space morphology and the urban heat island effect based on machine learning: a case study of Dali City, ChinaScientific Reports · 2026
- Toward a climate-resilient desert, coastal city: High-resolution LCZ–WRF modeling of transformative urban greening scenariosUrban Climate · 2026
- Microclimatic performance of greening against urban overheating: a multiseasonal analysis using in-situ monitoring and satellite data.Environment international · 2026
- Thermal Performance and Cooling-Energy Savings of Green Roofs in a Hot-Desert Climate: A Verified Coupled Envelope–HVAC Model for Mexicali, MexicoProcesses · 2026