BiogeosciencesOpen accessRhizosphere

Quantifying aggregation bias in marsh carbon flux estimates caused by rhizosphere oxygen heterogeneity

Youssef Saadaoui, Christian Beer, Peter Mueller, Friederike Neiske, Joscha N. Becker, Annette Eschenbach, Philipp Porada

Universität Hamburg · University of Münster

Key points

From the paper's conclusion
  • We calibrated an enzyme kinetic respiration function to marsh-soil incubations, then compared (I) respiration evaluated at a single mean O 2 value with (II) the mean of different respiration fluxes over a prescribed rhizosphere O 2 distribution.
  • For a gas-phase, air-equivalent O 2 proxy, the single mean approach overestimates respiration by ∼ 12 % on average.
  • Reporting the mean and variation of O 2 together with a calibrated KM,O2 allows modellers to anticipate or correct the bias associated with replacing heterogeneous rhizosphere conditions with a single mean.

Abstract

Oxygen (O 2 ) in marsh rhizospheres varies strongly at millimetre scales due to radial oxygen loss (ROL), re-oxidation of reduced compounds, hydrology, and sediment structure. Yet many models estimate heterotrophic (microbial) respiration at a single mean O 2 , which can bias CO 2 fluxes because the O 2 response of respiration is curved (nonlinear). We calibrated an enzyme kinetic respiration function to marsh-soil incubations, then compared (I) respiration evaluated at a single mean O 2 value with (II) the mean of different respiration fluxes over a prescribed rhizosphere O 2 distribution. To isolate oxygen effects, temperature and the relation between substrate and soil moisture were held fixed; incubations were used only to calibrate carbon kinetics. For a gas-phase, air-equivalent O 2 proxy, the single mean approach overestimates respiration by ∼ 12 % on average. This bias increases with increasing variation of O 2 and with the ratio of mean O 2 to the O 2 half-saturation constant KM,O2. In the dissolved phase, mean O 2 ≪ KM,O2 and variation in O 2 is small, so the bias is negligible due to linear behaviour of the relation in these conditions; when physiology is unit-matched to a similar relative saturation, however, the dissolved case shows a negative bias comparable to the gas-phase one. Our findings suggest reporting the mean and variation of O 2 together with a calibrated KM,O2 allows modellers to anticipate or correct the bias associated with replacing heterogeneous rhizosphere conditions with a single mean.

Read the paper

Discussion · 1

Science Skim's AI key points, plus readers' public thoughts

Science SkimAI key points
Pinned
  • We calibrated an enzyme kinetic respiration function to marsh-soil incubations, then compared (I) respiration evaluated at a single mean O 2 value with (II) the mean of different respiration fluxes over a prescribed rhizosphere O 2 distribution.
  • For a gas-phase, air-equivalent O 2 proxy, the single mean approach overestimates respiration by ∼ 12 % on average.
  • Reporting the mean and variation of O 2 together with a calibrated KM,O2 allows modellers to anticipate or correct the bias associated with replacing heterogeneous rhizosphere conditions with a single mean.

Readers' thoughts

No reader thoughts yet.

Related papers