Atmospheric Measurement Techniques

CloudMViT: cloud classification using ground-based remote sensing imagery and a lightweight hybrid architecture

Wei Xu, Ningning Wu, Lin Feng

Key points

From the paper's conclusion
  • Experiments on the World Meteorological Organization (WMO)-compliant HBMCD (10 standard cloud genera) and GCD (7 sky conditions) datasets demonstrate that CloudMViT achieves classification accuracies of 98.81 % and 95.13 %, respectively, significantly outperforming lightweight models such as MobileViT and EfficientNet.

Abstract

Ground-based remote sensing cloud imagery provides a valuable basis for analyzing regional cloud type distribution and temporal variation, supporting a wide range of applications that include water resource supply prediction and solar energy forecasting, where accurate cloud classification can significantly improve the estimation of surface solar irradiance and photovoltaic power output. However, existing cloud classification methods based on ground-based remote sensing imagery often suffer from limited recognition accuracy due to insufficient fine-grained feature extraction, and their large model parameter counts hinder deployment on embedded terminals. To address these issues, this study proposes CloudMViT, a lightweight hybrid network architecture fusing a dual-pooling channel attention module and cross-scale self-attention, which enhances both local and global feature representation of cloud images while optimizing computational efficiency. Specifically, the model suppresses sky background interference and strengthens cloud edge features via the dual-pooling channel attention module that combines global average pooling (GAP) and global max pooling (GMP); captures cross-channel detailed features (e.g., cirrus fibril structures and stratocumulus shadows) using depthwise separable convolution and a decoupling mechanism; and further reduces model parameters by introducing CloudGhost cascade compression technology through efficient feature redundancy elimination. Experiments on the World Meteorological Organization (WMO)-compliant HBMCD (10 standard cloud genera) and GCD (7 sky conditions) datasets demonstrate that CloudMViT achieves classification accuracies of 98.81 % and 95.13 %, respectively, significantly outperforming lightweight models such as MobileViT and EfficientNet. Ablation experiments validate the effectiveness of the dual-pooling channel attention module (improving accuracy by 5.31 %) and the CloudGhost module (increasing inference speed by 50 %). When deployed on the RK3588 embedded platform, the INT8-quantized CloudMViT enables real-time inference, maintaining an accuracy of 94.79 % with only 0.47 MB of memory occupation. The proposed cloud classification method and hardware acceleration strategy provide a feasible solution for the development of portable ground-based cloud observation and classification devices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers