Key points
From the paper's conclusion- The proposed architecture combines a modified secondorder generalized integrator phase-locked loop (MSOGI-PLL) with an adaptive frequency multi-resonant current controller (AFMRCC) to ensure accurate current tracking and effective harmonic compensation under distorted grid conditions.
Abstract
Grid-connected power electronic converters are highly sensitive to disturbances such as DC offset, frequency deviations, and voltage harmonics, which may degrade current control accuracy and overall power quality. This article presents an advanced control strategy for a single-phase five-level H-bridge inverter integrated into a photovoltaic (PV) grid-connected system. The proposed architecture combines a modified secondorder generalized integrator phase-locked loop (MSOGI-PLL) with an adaptive frequency multi-resonant current controller (AFMRCC) to ensure accurate current tracking and effective harmonic compensation under distorted grid conditions. The MSOGI-PLL provides robust phase and frequency synchronization even in the presence of voltage distortion and frequency variations, while the AFMRCC dynamically adjusts its resonant frequencies according to the estimated grid frequency, enabling selective suppression of dominant loworder harmonics, particularly the third, fifth, and seventh components. To further enhance power quality, an Inductor–Capacitor–Inductor (LCL) filter is employed in combination with a phase-disposition pulse-width modulation scheme to attenuate high-frequency switching harmonics and improve power quality at the point of common coupling. The proposed frequency-adaptive control strategy is developed and evaluated through detailed MATLAB/Simulink simulations of a 3.5 kW single-phase grid-connected PV system. Under nominal operating conditions, fast Fourier transform analysis demonstrates that the grid current total harmonic distortion is reduced to approximately 1.6%, in compliance with Institute of Electrical and Electronics Engineers 519 harmonic standards. To further assess the practical feasibility and robustness of the proposed controller under real-time operating constraints, a hardware-in-the-loop (HIL) implementation is carried out using the OPAL-RT OP4510 real-time simulator. The HIL results exhibit good agreement with the simulation outcomes, confirming the dynamic performance, robustness, and real-time implementation feasibility of the proposed control strategy for grid-connected PV applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Enhanced high-frequency stability and power quality in photovoltaic inverters via an optimized least mean square adaptive damping controllerResults in Engineering · 2026
- DSOGI-PLL and Moving Average Filter Based Control Method for Shunt Active Power FilterThe Eurasia Proceedings of Science Technology Engineering and Mathematics · 2026
- PV‐Fed Center‐Sourced Interleaved Multilevel Boost Converter–Fed H‐Bridge Inverter for High‐Power ApplicationsInternational Transactions on Electrical Energy Systems · 2026
- Multi-Objective Approach for Optimum Inverter Switching Frequency Selection Using Parabolic Carrier-Based PWM in Solar MicrogridsInventions · 2026
- LCL Grid-Connected Inverter Resonance Feedforward-Active Damping Hybrid Control Strategy for Mitigating Weak Grid Resonance and Harmonic CurrentsEnergies · 2025
- A Non-SOGI Single-Phase Frequency-Locked Loop Based on Synchronous Frequency Tracking Filter with Enhanced Immunity to Sensor-Induced DC Offsets.Sensors (Basel, Switzerland) · 2026