The impact of personal protective equipment on quality measures of upper gastrointestinal endoscopy.
Monika Pelczar, Klaudia Zielińska, Karolina Paks, Łukasz Wybrańczyk, Agnieszka Nowotarska, Andrzej Rak, Krzysztof Budzyń, Martyna Łęcka,
Division and Department of Gastroenterology and Hepatology, Medical University of Silesia, Katowice, Poland. · Department of Gastroenterology and Internal Medicine, Medical University of Bialystok, Poland.
Key points
From the paper's conclusion- Despite the use of personal protective equipment, gastroscopy quality indicators and cancer detection rates increased during the COVID-19 pandemic.
Abstract
INTRODUCTION: Esophagogastroduodenoscopy (EGD) is a frequently performed endoscopic procedure that is critical for detecting early neoplastic lesions in the gastrointestinal tract. During the COVID-19 pandemic, operators were forced to use personal protective equipment due to the risk of virus transmission during gastroscopy. AIM: This study aimed to determine the impact of the sanitary regime on the quality indicators of EGD. MATERIAL AND METHODS: Data from 12,322 patients who underwent diagnostic EGD between January 2019 and December 2021 performed in three endoscopy units were analysed. The evaluated parameters were as follows: composite detection rate (CDR), endoscopist biopsy rate (EBR), and upper gastrointestinal neoplasm detection (UGN). RESULTS: Of the patients, 6918 were female (56%), with a mean age of 58 years (IQR 24). Compared to the pre-pandemic period, during the pandemic (from 03.2020) there was an increase in UGN (3.1% vs. 4.6%, OR = 1.53, 95% CI: 1.26-1.86), CDR (26.0% vs. 31.1%, OR = 1.30, 95% CI: 1.20-1.41), and EBR (66.8% vs. 77.2%, OR = 1.69, 95% CI: 1.56-1.83). In the multivariate regression analysis, age (OR = 1.02, 95% CI: 1.02-1.03), male sex (OR = 1.5, 95% CI: 1.24-1.81), presence of alarm symptoms (OR = 3.93, 95% CI: 3.18-4.86), EGD performed during the COVID-19 pandemic (OR = 1.53, 95% CI: 1.24-1.89), and endoscopy performed in the centre K (OR = 3.01, 95% CI: 2.14-4.22) were related with UGN. CONCLUSIONS: Despite the use of personal protective equipment, gastroscopy quality indicators and cancer detection rates increased during the COVID-19 pandemic.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Differences in Endoscopy Characteristics Between Providers With the Highest and Lowest Post Endoscopy Upper Gastrointestinal Cancer Rates in EnglandUnited European Gastroenterology Journal · 2026
- Automated Device-Log Measurement of Process Indicators and Gastric Cancer Detection in Diagnostic Esophagogastroduodenoscopy: A Single-Center Retrospective Study.JGH open : an open access journal of gastroenterology and hepatology · 2026
- Nonvariceal Upper GI Bleeding in Established Users of Proton-Pump Inhibitors: Higher Incidence But Better OutcomesClinical and Translational Gastroenterology · 2026
- UK national analysis of colonoscopy quality in inflammatory bowel disease surveillance: a National Endoscopy Database (NED) cohort study.Journal of Crohn's & colitis · 2026
- The Classification for Adverse Events in GastRointEstinal Endoscopy (AGREE): Three-Year Evaluation and Additional Recommendations.Endoscopy international open · 2026
- The development and validation of artificial intelligence model to assess the degree of mucosal cleanliness of the upper gastrointestinal tract.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2026