High-resolution Manometry Catheter Insertion During Sedated Endoscopy; A Viable Option When Standard Intubation Fails.
James Endersby, Holly Mills, Humayra Dervin, Minerva De Silva, Natalia Zarate-Lopez, Rami Sweis
University College London Hospitals NHS Foundation Trust, London, UK. · Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK.
Key points
From the paper's conclusion- : Sedated EI of the HRM catheter enables protocol completion for patients unable to undergo routine testing, filling a key diagnostic gap while delivering manometric results comparable to standard, unsedated studies.
Abstract
BACKGROUND/AIMS: : When high-resolution manometry (HRM) intubation is not tolerated or the catheter fails to traverse the lower esophageal sphincter, the test is often abandoned, leaving patients without a diagnosis to guide therapy. Although endoscopic placement of HRM catheters under sedation has been described, no study has directly compared this approach with routine outpatient HRM. This study provides the first direct comparison of sedated endoscopic insertion (EI) versus routine insertion (RI). METHODS: : All patients who underwent EI of the HRM catheter between January 2020 and May 2025 were retrospectively reviewed and compared with a contemporaneous cohort who had RI. Each test included the standard protocol of ten 5 mL water swallows followed by a 200 g rice meal. Demographic data, endoscopic technique, sedation levels and manometric diagnoses were evaluated. Esophageal body function was defined in accordance with the Chicago classification version 4.0. RESULTS: : Of 88 patients who had EI attempted, 79 (89.8%) were successfully intubated to the stomach and 78 (88.6%) completed the full swallow protocol. Endoscopic visualization was required for passage through the cricopharynx in 47 (53.4%) and through the esophagogastric junction in 23 (26.1%), with manual guidance needed in 8 (9.1%). Intubation success was comparable to routine insertion (RI) (89.8% EI vs 80.7% RI; P = 0.089) but protocol completion was higher (88.6% EI vs 72.7%; P = 0.008). No adverse events occurred. CONCLUSIONS: : Sedated EI of the HRM catheter enables protocol completion for patients unable to undergo routine testing, filling a key diagnostic gap while delivering manometric results comparable to standard, unsedated studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The role of high-resolution manometry in the assessment of altered foregut anatomy: scoping review and interpretation recommendations.The American journal of gastroenterology · 2026
- Manometric Parameters of Esophagogastric Junction Competence Are Equivalent Predictors of Gastroesophageal Reflux Disease: A Head-To-Head Comparison.Neurogastroenterology and motility · 2026
- Biomechanical Assessment During High-Resolution Impedance Manometry Enhances Characterization of Inconclusive Esophagogastric Junction Outflow Obstruction.Neurogastroenterology and motility · 2026
- High-Resolution Manometry Assessment of Esophagitis Across Los Angeles Grades Validates Lyon 2.0 Criteria.Journal of clinical gastroenterology · 2026
- Validation of the Milan Score Using Prolonged Wireless PH MonitoringAlimentary Pharmacology & Therapeutics · 2026
- A novel endoscopy-guided airway management strategy for lateral decubitus endoscopic procedures.Frontiers in medicine · 2026